5. Installation
• Ensure the mains supply is switched off and the circuit supply fuses are
removed or the circuit breaker turned off.
• An isolating switch should be installed to the switch the power ON and OFF
to the luminaire. This allows the unit to be easily switched OFF for
maintenance purposes.
• Remove the diffuser from the base by turning 45 degrees anti-clockwise
and pulling away from the base of the luminaire.
• Select a suitable cable entry point either provided or by drilling into the base
ensuring not damage or infringe on any of the internal components.
• Mark the position of the mounting holes on the wall or ceiling.
• Drill the holes for the wall plugs ensuring not to infringe with any gas/water
pipes or electrical cables that may be hidden below the surface.
• Secure the230V AC 50Hz mains supply cable into the luminaire through the
hole(s) provided ensuring that a cable gland, grommet or sealing compound
is used to maintain the IP rating of the luminaire.
• Fix the luminaire using the correct screws for the wall plugs installed.
• Terminate the cable into the terminal block (See section 6. Connection Diagram
below) ensuring correct polarity is observed and that all bare conductors
are sleeved.
• Set the microwave sensor adjustments i.e. TIME, LUX and SENS using a thin
flat blade screwdriver (See section 7. Setting Up).
• Reposition the lens over the luminaire and twist clockwise to close.