6
Setting Up for Automatic Operation
• With the walk tests complete, the luminaire can be set up
for automatic operation.
• Use a thin flat blade screwdriver to make the adjustments.
TIME – Time ON Delay Setting
• The TIME setting controls how long the unit remains illuminated following
activation and after all motion ceases.
• The luminaire can be set to stay ON for any period of time between approx.
10 seconds (dial turned fully anti-clockwise) to approx. 30 minutes
(dial turned fully clockwise)
• Any movement detected during the ON period will instantly reset the timer.
• The LED indicator located above the three adjusters will flash when adjusting
the ON time delay;
1 flash
10 seconds (minimum time delay),
2 flashes
1 minute,
3 flashes
2 minutes,
4 flashes
5 minutes,
5 flashes
8 minutes,
6 flashes
10 minutes,
7 flashes
15 minutes,
8 flashes
20 minutes,
9 flashes
25 minutes,
10 flashes
30 minutes (maximum time delay).
Note: After the light switches OFF, it takes approx. 4 seconds before it is
able to start detecting movement again. The light will only switch ON
in response to movement once this period has elapsed.