background image

  1. 

VERIFY PRODUCT IS CORRECT

Pre-light using the wiring diagrams in this guide to power your 

ribbon/neon to ensure color/Kelvin temperature is correct.

Note: 

Do NOT connect max runs.

  

  2. 

TURN POWER OFF AT CIRCUIT BREAKER

SHOCK HAZARD! Turn power OFF at circuit breaker prior to 

installation, to avoid serious injury or death.

  3.

 DETERMINE LOCATION TO INSTALL

Dry-fit the lights to the desired location BEFORE removing the 

adhesive backing. Refer to the 

CONFIGURATION GUIDE

 for a list 

of products and zone locations. 

Skip to step 6 to mount the ribbon without a channel.
Skip to step 10 to mount neon.

  4. 

CUTTING THE CHANNEL FOR RIBBON

To determine the cut length, place the LED ribbon beside the 

channel, add 1” to account for the Lead Lock Heat Shrink around 

the lead. Snap the lens and end cap into place and secure with 

masking tape at the cut mark to protect the lens from cracking.

Cut using metal rated saw blade. If cut is rough, use a metal file to 

smooth the edges. Clean any remaining slivers of metal or plastic 

to insure a clean install.

If installing Surface 1707 or Surface 1919: After cutting, remove 

lens and measure 0.39” from end and cut just the lens to 

account for the end cap. 

  5.

 MOUNTING THE RIBBON IN CHANNEL

a.

 Channel, directly to the Surface

Install channel directly to the surface with the provided screws. 

You will need to pre-drill the holes before installation or use 

self- tapping screws when installing onto metal.

b.

 Channel with Clips

Screw clips to the surface at the beginning and end of 

each section and then about every 1.5 ft in between. For 

certain channels, you can utilize the clips to connect channel 

(see diagram).

c.

 Universal Clips

Attach the provided channel clips to the Universal 

Clips. Then install at least four clips for every 2M 

of channel, to the surface with screws. Snap your channel into 

the channel clips and secure the channel by pinching the clips 

around the channel. 

d.

 Mud-In

Prep the wall for the channel base by measuring the 

channel width and cutting into the drywall. Then, slide the 

channel in the wall, with the wings resting on the drywall. 

(Optional: Secure the channel in place by using screws in the 

mud-in holes.)Then, mud over the wings to secure the channel.

  6. 

PREP SURFACE PRIOR TO INSTALLING RIBBON

To ensure lasting bond, use the provided alcohol wipe to prep the 

surface. For slippery surfaces, pre-sand the area before installing 

the lights or use the 3M Primer 94. 

  7. 

INSTALL END CAP WITH HOLE (OPTIONAL)

Slide the lead through the hole of the end cap and snap it into the 

channel and confirm the fit. If lead is to the back, drill hole through 

the channel for the lead to go through.

  8. 

MOUNT THE RIBBON

Once fit is confirmed, begin peeling the backing and gently 

pressing the ribbon into place, slowly working your way towards 

the end of the ribbon. This process will make it easier to handle 

the ribbon, especially in longer runs. In channel, center the ribbon 

starting 1/8” away from the end cap with the hole.

Note: 

Adhesive MUST BE REMOVED for proper heat dissipation. 

Do not let the LEDs hang when installing, as this could add 

stress to the solder connections.

  9. 

INSTALL LENS (OPTIONAL)

Once the ribbon is in place, install the lens by pressing it into 

place, starting from one end and working your way to the other, 

then snap the solid end cap onto the open end.

10. 

CUTTING THE CHANNEL FOR NEON

Measure the length of the neon and subtract 3.62” to allow room 

for the end caps

Then measure the length of the channel and 

mark on the channel where you plan to cut.

Example: 35” run of neon would need to have a 31.38” channel.

Cut using a metal rated saw blade. If cut is rough, use a metal 

file to smooth the edges. Clean any remaining slivers of metal to 

insure a clean install.

11.

 MOUNTING THE NEON WITH CHANNEL OR CLIPS

Install channel or clips directly to the surface with screws. You will 

need to pre-drill the holes before installation or use self-tapping 

screws when installing onto metal.
Then gently press neon into the channel/clip, where it will lock 

into place with the locking clamps. If you need to remove the 

neon, use a pliers to gently pinch the clamps to pull the neon out.

12.

 TURN POWER ON AT CIRCUIT BREAKER

Once your ribbon or neon is connected, turn the power on at the 

circuit breaker.

INSTALLATION GUIDE 

RIBBON, NEON & CHANNEL

ATTENTION: 

This product should be installed by a professional, licensed electrician.

Do not attempt to make sharp bends. 

Excessive or exaggerated bending and twisting can damage the circuit. 

NOTE: IP65 is water resistant & IP68 is protected against water; power supply is NOT. 
Cutting Ribbon or Neon in the field may void the UL Certification and Warranty.

Continued on next page

novaflexled.com 

 

|

  

1

Содержание RIBBON Series

Страница 1: ...LING RIBBON To ensure lasting bond use the provided alcohol wipe to prep the surface For slippery surfaces pre sand the area before installing the lights or use the 3M Primer 94 7 INSTALL END CAP WITH HOLE OPTIONAL Slide the lead through the hole of the end cap and snap it into the channel and confirm the fit If lead is to the back drill hole through the channel for the lead to go through 8 MOUNT ...

Страница 2: ...this product in its proper manner could result in severe injury and or property damage Keep out of reach of children This product is provided by the manufacturer as is with all faults without any warranties or representations express or implied including but not limited to the warranties of merchantability or fitness for a particular purpose In no event shall manufacturer be liable for any special...

Страница 3: ... MLV Non Dimming Non Dimming Static Ribbon or Neon Static Ribbon or Neon Static Ribbon or Neon Electronic Hardwire AC POWER 120 VAC Switch Non Dimming Only NF PS HLG100W2V HW will have a ground wire Ground L Brown Blue CN Blue ACL Brown V Red V Black INPUT OUTPUT Ground N Static Ribbon or Neon Plug Play AC POWER NF C Y NF C MF Static Ribbon or Neon Static Ribbon or Neon Static Ribbon or Neon 0 10 ...

Страница 4: ...24V HW 120V AC Line 120V AC Line INPUT OUTPUT W B G R V NF S3i WR 1009 NF PS HLG100W 24V HW NF PS HLG100W 24V HW 120V AC Line 120V AC Line INPUT OUTPUT W B G R V V V Red Wire R Green Wire G Blue Wire B Black Wire V S3i Wireless Receiver Adjustable Run 1 Run 2 Adjustable Ribbon or Neon Adjustable Ribbon or Neon NF A UNV INPUT W B G R v v OUTPUT W B G R V V V Black Wire V Yellow Wire Orange V White ...

Отзывы: