background image

 

 
 

_______________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e-2-s.com             Fax: +44 (0)208 740 4200 
Document No. IS 2492-P          Issue D         18-03-10

                     

Sheet 1 of 4                                                                                                       (1)

 

INSTRUCTION MANUAL (ATEX / IECEx) 

BExBG21D   Flameproof Xenon Beacon 

For use in Flammable Gas and Dust Atmospheres 

 

 
 
 
 
1)  Introduction 

 
The BExBG21D is a flameproof beacon certified to meet the 

requirements  of  the  ATEX directive 94/9/EC  and  the IECEx 
scheme. The beacon produces  synchronised  visual  warning 

signals  and  can  be  used  in  hazardous  areas  where 
potentially  flammable  gas  and  dust  atmospheres  may  be 

present.  The  BExBG21D  has  can  be  used  in  Zone  1  and 
Zone  2  areas  with  gases  in  groups  IIA,  IIB  and  IIC  and 
Temperature  Classifications  of  T1,  T2,  T3  and  T4  in  an 

ambient  temperature  up  to  +55ºC.  The  beacon  can  also be 
used  at  an  ambient  temperature  up  to  +70ºC  with  a  

temperature  classification  of  T3.  The  units  can  be  used  in 
Zone 21 and Zone 22 areas for combustible dusts and have 

an  IP  rating  of  IP  67  and  a  surface  temperature  rating  of 
T135ºC  if  the  upper  ambient  temperature  is  restricted  to 

+55ºC or T200ºC  with  an  the  upper  ambient  temperature  of 
+70ºC.    The  BExBG21D  beacon  has  two  xenon  tubes  and 
can produce three different flash patterns. 

 

2)  Marking 

 

All  units  have  a  rating  label,  which  carries  the  following 
important information:- 

 
Unit Type No.    

BExBG21D

 

 

Input Voltage:    DC Units    24V  or  48V 

            AC Units    230V  or 115V 

 

Code:   

Ex d IIC T4 Ta –50ºC to +55ºC 
Ex d IIC T3 Ta –50ºC to +70ºC 

Ex tD A21 IP67 T135ºC based on max Ta of +55ºC 
Ex tD A21 IP67 T200ºC based on max Ta of +70ºC 

 

 

Certificate No’s

    KEMA 00ATEX2006 

 

 

IECEx KEM 10.0002 

 

       

 

 

 

 

 

 

Warnings: 

 

DO NOT OPEN WHEN AN EXPLOSIVE                        

 

              GAS OR DUST ATMOSPHERE IS PRESENT 

 

      COVER BOLTS CLASS A4-80 

 
 

 USE HEAT RESISTING CABLES AND CABLE GLANDS 

  

(Rated 110ºC) AT AMB. TEMPERATURES OVER 40ºC 

 

 

 

Year of Construction/ 

i.e.  10 / 1DB72000001 

Serial No. 

 

 
 
 
 

3) 

Type Approval Standards

 

 

The beacon has EC Type Examination and IECEx certificates 
issued  by  KEMA  and  has  been  approved  to  the  following 

standards:- 
 

EN60079-0:2006   IEC60079-0:2004 (Ed4)

      

General Requirements

 

EN60079-1:2007   IEC60079-1:2007

 

(Ed6)

        Flameproof Enclosure ‘d’ 

 
EN61241-0:2006   IEC61241-0:2004 (Ed1)       Dust General 

          Requirements 

EN61241-1:2004   IEC60079-1:2004 (Ed1)       Dust Enclosures tD 

 

 

4) 

Installation Requirements

 

 
The  beacon  must  be  installed  in  accordance  with  the  latest 
issues  of  the  relevant  parts  of  the  BS  EN  60079 

specifications  or  the  equivalent  IEC  specifications  – 
Selection,  Installation  and  maintenance  of  electrical 

apparatus for use in potentially explosive atmospheres (other 
than  mining  applications  or  explosive  processing  and 

manufacture):- 
 

EN60079-14:2008

    

Electrical Installations in Hazardous 

IEC60079-14:2007 (Ed4) 

Areas (other than mines)

 

 

EN60079-10:2003

   

Classification of Hazardous Areas

 

IEC60079-10:2008 (Ed1) 

 

The installation of the units must also be in accordance with 
any  local  codes  that  may  apply  and  should  only  be  carried 

out  by  a  competent  electrical  engineer  who  has  the 
necessary training. 

 

5) 

Zones,  Gas  Group,  Category,  IP  Rating  and 
Temperature Classification 

 

The BExBG21D beacon has been certified Ex d IIC T3 Ta –

50ºC  to  +70ºC  and  Ex d IIC  T4 Ta  –50ºC  to  +55ºC for gas 
and Ex tD IP67 T200ºC based on max Ta +70ºC and T135ºC 

based on max Ta +55ºC for dust. This means that the units 
can be installed in locations with the following conditions:- 
  

Area Classification Gas: 

 

Zone 1 

Explosive  gas  air  mixture  likely  to  occur  in 

normal operation. 

Zone 2 

Explosive  gas  air  mixture  not  likely  to  occur, 

and if it does, it will only exist for a short time. 

 

Gas Groupings: 

 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC 

Hydrogen and Acetylene 

 

Temperature Classification: 

 

T1 

400

o

 C  

Amb. +70ºC 

T2 

300

o

 C 

Amb. +70ºC 

T3 

200

o

 C 

Amb. +70ºC 

T4 

135

o

 C 

Amb. +55ºC 

0518 

CE Marking 

Notified Body No. 

90º 

II 2G/D 

Epsilon x: 

Equipment Group and 
Category: 

Содержание BExBG21D

Страница 1: ...AT RESISTING CABLES AND CABLE GLANDS Rated 110ºC AT AMB TEMPERATURES OVER 40ºC Year of Construction i e 10 1DB72000001 Serial No 3 Type Approval Standards The beacon has EC Type Examination and IECEx certificates issued by KEMA and has been approved to the following standards EN60079 0 2006 IEC60079 0 2004 Ed4 General Requirements EN60079 1 2007 IEC60079 1 2007 Ed6 Flameproof Enclosure d EN61241 0...

Страница 2: ...er To achieve this remove the four M6 hexagon socket head screws see figure 2 and withdraw the flameproof cover taking extreme care not to damage the flameproof joints in the process Note the four M6 screws are Class A4 80 stainless steel and only screws of this category can be used on these beacons It is therefore important that these screws and their spring washers are kept in a safe place durin...

Страница 3: ... approved for Ex d applications can be used which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN60079 14 2008 IEC60079 14 2007 When only one cable entry is used the other one must be closed with an Ex d flameproof blanking plug which must be suitably approved for the installation requirements For combustible dust app...

Страница 4: ...three different flash patterns as listed below The flash patterns are set internally by the selection of pin headers On the DC beacons the flash pattern set can be changed externally to produce a second stage by connecting terminal S2 to ve supply line The AC beacons do not have a second stage DC Beacons Stage 2 Single Flash 1Hz Both tubes flashing together AF Alternate Flash 2Hz Tubes flashing al...

Отзывы: