pump in Standy Mode (“Drain Mode”). In this case, press any other but-
ton to exit. System will will revert to previous mode after 1 hour.
Jets 1
Press the “Jets 1” button once to turn pump 1 on or off, and to shift be-
tween low and high speeds if equipped. If left running, the pump will turn
off after a timeout period. The pump 1 low speed timeout on some sys-
tems may be as long as 4 hours.
On non-circ systems, the low speed of pump 1 runs when the blower or
any other pump is on. It may also activate for at least 1 minute every 30
minutes to detect the spa temperature (polling) and then to heat to the
set temperature if needed, depending upon mode. When the low speed
turns on automatically, it cannot be deactivated from the panel; however,
the high speed may be started.
Jets 2
(optional on some systems)
Press the “Jets 2” button once to turn pump 2 on or off, and to shift be-
tween low and high speeds if it is a two-speed pump. If left running, the
pump will turn off after a timeout period.
Invert
Press the “Warm” or “Cool” button, then “Blower” to change the numbers
in the display to read upside down. Repeat sequence to return the dis-
play to it’s normal right- side-up display.
Note: If your system does not have a “Blower” button, use “Jets 3” in-
stead.
Preset Filter Cycles
On all systems, the pump and the ozone generator will run during filtra
-
tion. At the start of each filter cycle, the blower will run briefly on its
19
highest speed to purge the air channels. The lowest speed of any other
pumps and the mister will also run briefly. On some circ systems, pump
1 may also run for the duration of the filter.
(The following is specific to all systems that are programmed ac
-
cording time.)
There are two filter cycles per day. The start/end times of each cycle
are programmable. To program set time as instructed above, then press
“Mode/Prog” to advance to the next setting (or to exit after the last set-
ting). Default filter cycles can vary from system to system. A common
Содержание Premium EP-14
Страница 1: ...Part 11 0096 11...
Страница 2: ...This manual covers your new 2009 TidalFit...
Страница 13: ...9 60Hz GFCI WIRING DIAGRAM...