Version 09/2018
8 Servicing / Maintenance
8.1 Maintenance period
Maintenance of the machine should take place within the framework of central
maintenance of the elevator, at least once a year.
8.2 Maintenance measures
OK
Work step
1. Check the oil level and top up if necessary.
Chapter8.3.3
2. Change the oil when the change date is reached.
Chapter
3. Check the brake shoes for wear; the remaining lining
thickness must be at least 3 mm.
Chapter 8.5
4. Check the brake setting; the shoe stroke should be 0.3 + 0.1
mm.
Chapter 8.7
5. Check the braking deceleration.
Chapter 8.6
6. Check the armature base plate setting and its ease of
movement.
Chapter8.7
7. Check worm gear toothing for wear.
8. Check the backlash between the worm shaft and worm
wheel.
Chapter8.4
9. Check the groove profile on the traction sheave for damage
and wear.
10. Check that the bolts of the traction sheave mount are
securely seated.
Chapter 10.2
11. Check rope pulley grooves for damage and wear.
12. Check proper and adequate condition and safety of electrical
connections.
13. Check that protective and safety devices are present and
correctly set.
Table 8.2-1