September 6, 2006
K2 Storage System Instruction Manual
335
Virus scanning and protection policies
and installed application software) from a PC that is running the scanning program
while the K2 computers are being used to record or play video to air. The anti-virus
package executing on the PC can be scheduled to scan the system drives of multiple
K2 Systems.
The following strategies are recommended for virus scanning:
• Run the scanning software on a dedicated PC that connects to the K2 system via a
network mount. Do not run scanning software locally on the K2 system.
• Connect to the K2 computer via 100BaseT network. This constrains the bandwidth
and system resources consumed, so as to not interfere with media operations. Do
not connect and scan via Gigabit Ethernet.
• Grass Valley does not support the running of anti-virus programs on a K2 computer
itself at the same time the system is being used to record or play video to air.
With these recommended strategies, you should be able to scan K2 computers without
interrupting media access.
In addition, the following protection policies are recommended:
• Where possible, K2 systems should be run in a closed and protected environment
without network access to the corporate IS environment or the outside world.
• If the K2 system must operate in a larger network, Grass Valley recommends that
access be through a gateway or firewall to provide anti-virus protection. The
firewall should allow incoming HTTP (TCP ports 80 and 280) connections for
client and configuration connections to the K2 system inside the private network.
Additionally, ports should allow incoming packets so requests can be properly
processed. The port that needs to be open is port 445 for TCP and UDP for
Windows and SAMBA shares. If your site’s policies require that these port
numbers change, contact Grass Valley support for assistance.
• Access to the K2 system should be controlled in order to limit the likelihood of
malicious or unintended introduction of viruses.
• The front and rear USB ports of K2 systems should normally be disabled; they
should only be used by Windows administrators. On a K2 Media Client, be careful
that you do not disable the internal USB connection to the RS-422 boards. Refer to
the K2 Media Client System Guide.
Содержание K2
Страница 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 1 071 8461 01 SEPTEMBER 2006 ...
Страница 14: ...14 K2 Storage System Instruction Manual September 6 2006 Safety Summaries ...
Страница 20: ...20 K2 Storage System Instruction Manual September 6 2006 Finding Information ...
Страница 24: ...24 K2 Storage System Instruction Manual September 6 2006 Chapter 1 Product Description ...
Страница 94: ...94 K2 Storage System Instruction Manual September 6 2006 Chapter 3 Installing the Level 2 Storage System ...
Страница 148: ...148 K2 Storage System Instruction Manual September 6 2006 Chapter 4 Installing the Level 2R Storage System ...
Страница 254: ...254 K2 Storage System Instruction Manual September 6 2006 Chapter 6 Installing the Level 3R Storage System ...
Страница 296: ...296 K2 Storage System Instruction Manual September 6 2006 Chapter 7 Installing the Nearline Storage System ...