Chapter 7 Installing the Nearline Storage System
Using FTP for file transfer
Since the Nearline system has no media database, procedures that apply to “online”
K2 storage systems (Levels 1, 2, 3, and 4) do not globally apply to the Nearline
storage system. This includes procedures for streaming, import, export, and FTP.
2.
Power-on the Ethernet
switch.
This description is for the HP
ProCurve switch.
The switch performs its diagnostic self test, which takes
approximately 50 seconds to complete. LED Behavior during the
self test is as follows:
•
Initially, all the status, LED Mode and port LEDs are on
for most of the duration of the test.
•
Most of the LEDs go off and then may come on again
during phases of the self test. For the duration of the self
test, the Test LED stays on.
When the self test completes successfully, the Power and Fan
Status LEDs remain on, the Fault and Test LEDs go off, and the
port LEDs on the front of the switch go into their normal
operational mode, which is as follows:
•
If the ports are connected to active network devices, the
LEDs behave according to the LED Mode selected. In the
default view mode (Link), the LEDs should be on.
•
If the ports are not connected to active network devices,
the LEDs will stay off.
If the LED display is different than what is described above,
especially if the Fault and Test LEDs stay on for more than 60
seconds or they start blinking, the self test has not completed
correctly. Refer to the manual you received with the switch for
troubleshooting information.
3.
Power-on RAID storage
devices.
Power-on expansion chassis (if present) prior to or simultaneous
with the power-on for the main Fibre Channel chassis.
NOTE: Always power-on the RAID Expansion
chassis prior to, or simultaneously with the
RAID Controller chassis.
Verify that start-up indicators show normal start-up processes, as
follows:
•
DIR and SVP LEDs on the RAID controllers are blinking
green
•
Disk Link LED is steady ON green.
•
FLT and BAT LEDs are OFF.
•
The front Power LED is ON, Service LED is OFF after
about 5 minutes.
Refer to the
L3 RAID
Instruction Manual to interpret other
disk access LED or status LED behavior.
4.
Power-on any K2 Media
Server.
Flip down the front bezel and press the stand-by button.
The LCD display lights during normal system operation.
Wait until start up processes are complete before proceeding.
When the server responds to the ping command, startup is
complete. If you are not sure, wait 10 minutes.
5.
Power-on the remaining K2
Media Servers.
Flip down the front bezel and press the stand-by button.
The LCD display lights during normal system operation.
Wait until start up processes are complete before proceeding.
When the server responds to the ping command, startup is
complete. If you are not sure, wait 10 minutes.
Device
Verification instructions
Содержание K2
Страница 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 1 071 8461 01 SEPTEMBER 2006 ...
Страница 14: ...14 K2 Storage System Instruction Manual September 6 2006 Safety Summaries ...
Страница 20: ...20 K2 Storage System Instruction Manual September 6 2006 Finding Information ...
Страница 24: ...24 K2 Storage System Instruction Manual September 6 2006 Chapter 1 Product Description ...
Страница 94: ...94 K2 Storage System Instruction Manual September 6 2006 Chapter 3 Installing the Level 2 Storage System ...
Страница 148: ...148 K2 Storage System Instruction Manual September 6 2006 Chapter 4 Installing the Level 2R Storage System ...
Страница 254: ...254 K2 Storage System Instruction Manual September 6 2006 Chapter 6 Installing the Level 3R Storage System ...
Страница 296: ...296 K2 Storage System Instruction Manual September 6 2006 Chapter 7 Installing the Nearline Storage System ...