September 6, 2006
K2 Storage System Instruction Manual
135
Configuring the media server - Part 2
iSCSI Bridge Server
Configuration
This page manages the
components that bridge
between iSCSI (the GigE
media network) and the
Fibre Channel connection to
the RAID storage. You
configure network settings
on the iSCSI adapters and
the page validates that the
Fibre Channel adapter is in
place and that the media
LUNs are visible as iSCSI
targets.
For Level 2 redundant, select
Primary
.
Select an iSCSI adapter and click
Modify
. A network configuration
dialog box opens. Enter the media network IP address and the subnet
mask and click
Apply
. Do the same for the other iSCSI adapter.
Click
Check
. The Validation Report opens.
Confirm that the iSCSI configuration is successful. Close the Validation
Report and then click
Next
.
Database Server
Configuration
Enter the name or IP address of K2 Media server B. This is the redundant
partner of the server you are now configuring.
Click
Next
.
On this page…
Do this…
Содержание K2
Страница 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 1 071 8461 01 SEPTEMBER 2006 ...
Страница 14: ...14 K2 Storage System Instruction Manual September 6 2006 Safety Summaries ...
Страница 20: ...20 K2 Storage System Instruction Manual September 6 2006 Finding Information ...
Страница 24: ...24 K2 Storage System Instruction Manual September 6 2006 Chapter 1 Product Description ...
Страница 94: ...94 K2 Storage System Instruction Manual September 6 2006 Chapter 3 Installing the Level 2 Storage System ...
Страница 148: ...148 K2 Storage System Instruction Manual September 6 2006 Chapter 4 Installing the Level 2R Storage System ...
Страница 254: ...254 K2 Storage System Instruction Manual September 6 2006 Chapter 6 Installing the Level 3R Storage System ...
Страница 296: ...296 K2 Storage System Instruction Manual September 6 2006 Chapter 7 Installing the Nearline Storage System ...