264
K2 Storage System Instruction Manual
September 6, 2006
Chapter 7 Installing the Nearline Storage System
• If you do not have trunks, select all ports.
• If you have trunks, select the remaining ports (the ports not trunked).
7. Click
Modify Selected Ports
.
8. Make sure Port Enabled is set to
Yes
, leave Mode as default of
Auto
and set Flow
Control to
Disable
.
9. Click
Apply Settings
.
NOTE: If the switch is used for the Nearline system only and there is no K2 media
(real-time iSCSI) traffic on the switch, there is no need to configure VLANs.
10.Close the switch configuration application.
Setting up the K2 media server
Do the following to prepare each K2 media server:
• Provide power to the servers.
Do not connect the iSCSI ports. They are not used for the Nearline storage
system.
Connect the motherboard GigE port 1 and GigE port 2 to control ports on the
GigE switch.
iSCSI interface
Power
Keyboard/Mouse
GigE
3
2
1
Fibre Channel
VGA monitor
GigE
(FTP) (control)
ports
(not used)
port 1
(USB)
Serial port
port 2
Содержание K2
Страница 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 1 071 8461 01 SEPTEMBER 2006 ...
Страница 14: ...14 K2 Storage System Instruction Manual September 6 2006 Safety Summaries ...
Страница 20: ...20 K2 Storage System Instruction Manual September 6 2006 Finding Information ...
Страница 24: ...24 K2 Storage System Instruction Manual September 6 2006 Chapter 1 Product Description ...
Страница 94: ...94 K2 Storage System Instruction Manual September 6 2006 Chapter 3 Installing the Level 2 Storage System ...
Страница 148: ...148 K2 Storage System Instruction Manual September 6 2006 Chapter 4 Installing the Level 2R Storage System ...
Страница 254: ...254 K2 Storage System Instruction Manual September 6 2006 Chapter 6 Installing the Level 3R Storage System ...
Страница 296: ...296 K2 Storage System Instruction Manual September 6 2006 Chapter 7 Installing the Nearline Storage System ...