September 6, 2006
K2 Storage System Instruction Manual
263
Setting up the Nearline GigE switches
5. If you do not need trunks, such as on a one-switch system, skip to the next step in
this procedure. If you need trunks, such as on a two-switch system with ISLs, do
the following:
a. Select (Ctrl + Click) the trunked ports. Typically the trunked ports are at the
bottom of the list. In the configuration for 10 Gig ISLs, ports 25 and 26 are Trk1.
b. Click
Modify Selected Ports
.
c. For the trunked ports, set Port Enabled to
Yes
. The 10 Gig ISL ports are disabled
by default, so make sure you enable them. Leave Mode as default of
Auto
, and
set Flow Control to
Disable
.
d. Click
Apply Settings
.
6. On the Port Configuration page, do one of the following:
Содержание K2
Страница 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 1 071 8461 01 SEPTEMBER 2006 ...
Страница 14: ...14 K2 Storage System Instruction Manual September 6 2006 Safety Summaries ...
Страница 20: ...20 K2 Storage System Instruction Manual September 6 2006 Finding Information ...
Страница 24: ...24 K2 Storage System Instruction Manual September 6 2006 Chapter 1 Product Description ...
Страница 94: ...94 K2 Storage System Instruction Manual September 6 2006 Chapter 3 Installing the Level 2 Storage System ...
Страница 148: ...148 K2 Storage System Instruction Manual September 6 2006 Chapter 4 Installing the Level 2R Storage System ...
Страница 254: ...254 K2 Storage System Instruction Manual September 6 2006 Chapter 6 Installing the Level 3R Storage System ...
Страница 296: ...296 K2 Storage System Instruction Manual September 6 2006 Chapter 7 Installing the Nearline Storage System ...