1.
Make sure that the device is turned off, disconnected from the mains and com‐
pletely cooled down.
2.
Move the head of the unit in a horizontal position. The sticker “Open this side
to change lamp” has to be on the top. Secure the head with both locking levers
against rotation.
3.
Open the housing by unscrewing the four Phillips top screws marked in the
illustration above by ‘A’ and remove the upper part of the housing. Make sure
that no screw falls inside the unit.
4.
Check that you have removed the proper cover. Compare the exposed interior
of the unit with the illustration. If you can see the heat sensor (marked in the
illustration by ‘D’) at this point, the proper side of the case has been opened. If
the correct side of the case is open, you can also clearly see the colour wheel
(in the figure marked by ‘E’).