5.
Loosen the two Phillips screws holding the illuminant cover (marked in the
illustration by ‘C’) and remove the illuminant cover.
6.
Press the illuminant against the spring tension down and tilt it so far back, until
you can remove it upwards out of the holder.
7.
Unplug the two flat connectors with the pliers from the old illuminant.
8.
Connect the two flat connectors to the new illuminant. Secure the new illumi‐
nant using the spring clips. Check the secure fit.
9.
Reattach the illuminant cover and secure it with the two Phillips screws
(marked in the illustration by ‘C’).
10. Put the upper part of the housing back on the base. At that point, both
housing parts must engage in the circumferential seal profile. Replace the four
Phillips screws (‘A’) to the top of the housing and tighten them.
Maintenance