17
Technical data
EcoLogic
25
EcoLogic
35
EcoLogic
44
EcoLogic
55
Performance (measured
according to EN 303-5: 2012)
Maximum power
kW
25
35
44
55
Minimum power
kW
8
11
13
17
Electrical conection
V,Hz
230 V, 50 Hz
230 V, 50 Hz
230 V, 50 Hz
230 V, 50 Hz
Electrical conection (current)
A
10
10
10
10
Boiler class
5
5
5
5
General information
Max. Permited presure
bar
2,5
2,5
2,5
2,5
Max. Permited temperature
°C
85
85
85
85
Min. permited return temperature
°C
55
55
55
55
Fuel
EN PLUS - UNI EN 14961 - 2 (UNI EN ISO 17225-2) Class A1 / A2
Pellet consumption min / max
kg
1,7 / 5,4
2,4 / 7,5
3 / 9,5
3,9 / 11,9
Pellet silo capacity
kg
170
170
170
200
Fresh air opening
cm
30x15
30x15
30x15
30x15
Technical data
Boiler width with pellet silo
mm
1050
1050
1050
1050
Height
mm
1270
1460
1460
1650
Depth
mm
1100
1100
1100
1100
Water content
l
55
68
90
115
Weight
kg
370
395
415
455
Height out / return
mm
1125 / 603
1315 / 603
1315 / 685
1505 / 685
Chimney underpresure
Pa /
mbar
5 / 0,05
5 / 0,05
5 / 0,05
5 / 0,05
Flue gas pipe height (direction UP)
mm
1250
1440
1440
1630
Flue gas pipe diameter
Ø
130
130
130
130
* minimal power - 30 % maximum
power
Содержание EcoLogic 25
Страница 2: ...2...
Страница 22: ...22 Hydraulic conection diagrams...
Страница 23: ...23...
Страница 24: ...24...
Страница 25: ...25...
Страница 26: ...26...
Страница 27: ...27...
Страница 28: ...28...
Страница 34: ...34...
Страница 61: ...61 Clean the dust or dirt on the surface that sits on the seal of a heat exchanger box smaller box 1...