METAL FLEXIBLE HOSES MUST NOT BE USED AS A FLUE
PIPES!
ALL PARTS OF THE FLUE GAS DUCT SHOULD BE SAFE AND
REPLACEABLE, ALLOWING INTERNAL CLEANSING.
AVOID HORIZONTAL DEVIATION.
Boiler can not be conected to:
to a chimney or flue pipe to which it is already connected and
used by another source of heat (gas boilers, boilers and wood
stoves, pellet boilers etc.)
ventilation systems.
If the chimney produces pressure over 20 Pa, the regulation can be done in several
ways. One of the ways (but less advisable) is to open a little door for cleaning.
Our recommendation is to install the throttle regulator (ie, zugregler, draft
regulator).
1 ; 3
2
1 ; 3
The picture shows the way the regulator is assembled. There are models that
are built into the wall (1 and 3) and the models that are installed on the flue pipe.
(2)