Note: When setting boiler temperature and heating circuit.
The heating circuit temperature is lower than the default boiler
temperature
During operation, the regulation follows the default temperature of the HEATING CIRCUIT. If this
temperature is lower than the set temperature of the BOILER , the regulation will turn off the boiler as
soon as it reaches the HEATING CIRCUIT temperature, increased for hysteresis. The display will show
BOILER PAUSE.
The heating circuit temperature is higher than the default boiler
temperature
During operation, the control follows the set temperature of the HEATING CIRCUIT and if this
temperature is higher than boiler set temperature, the control will turn off the boiler as soon as it
reaches the HEATING CIRCUIT temperature. The display will show BOILER OFF EXTINGUISHING
HEATING C MIXING VALVE
When one of the heating circuits is activated with the mixing valve, three more operation settings are
displayed:
HEATING CIRCUIT
PUMP + MIXING VALVE
Select a HEATING C MIXING
VALVE in the user menu and press the SET
button
HEATING CIRCUIT
HC. flow set temp
.
40
WORK : 50
.
Setting the output temperature to the
heating circuit (sensor must be placed
after the mixing valve) eg floor
heating
HEATING CIRCUIT
WORK TIME MIXER
90 SEC
WORK : 90
.
Setting the time of the work for
mixing valve
HEATING CIRCUIT
MIN. TIME WORK M. VALVE
1 SEC
WORK: 0,30
.
Setting the minimum time mixing
valve
Содержание EcoLogic 25
Страница 2: ...2...
Страница 22: ...22 Hydraulic conection diagrams...
Страница 23: ...23...
Страница 24: ...24...
Страница 25: ...25...
Страница 26: ...26...
Страница 27: ...27...
Страница 28: ...28...
Страница 34: ...34...
Страница 61: ...61 Clean the dust or dirt on the surface that sits on the seal of a heat exchanger box smaller box 1...