TROUBLESHOOTING
During boiler operation there are possible errors that can be eliminated without
calling customer service.
No power
In the event of a power failure, there are no signs in the display. It is necessary to check the supply
fuse in the house and the main fuse on the boiler located on the side of the boiler. If the fuse is blown,
it must be replaced.
ERROR
Possible ERROR - SOLUTION
Attention High temp./ STB activated
Activated STB switch (overheating of the boiler)
Sensor Buufer up/ Sensor buffer
down/ Boiler temperature/ Return
temperature / Burner termperature /
Sensor sanitary boiler/ Sensor temp.
Out. interruption/ Short circuit
Some of these sensors is broken or interrupted
connection.
In the case of a senso-error, one of the sensors
always has the capability to terminate the connection
or short circuit of the sensor.
Call the service
Grate does not work
The grate in the burner does not work. Open the fire
door and see if anything prevents the grate from
running.
Call service if it is not possible to start operation.
Smoke fan fault
The flue gas fan does not work. Check the connection
cables. Remove the cover of the heat exchanger and
check if something prevents startup of fan blades.
Call service if it is not possible to start operation.
Ignition failed
Check the pellet is in the tank. Something may cause
stuck. Check if the motorreductor and spiral for the
pellet
Make sure the heater is correct.
Call the service
Содержание EcoLogic 25
Страница 2: ...2...
Страница 22: ...22 Hydraulic conection diagrams...
Страница 23: ...23...
Страница 24: ...24...
Страница 25: ...25...
Страница 26: ...26...
Страница 27: ...27...
Страница 28: ...28...
Страница 34: ...34...
Страница 61: ...61 Clean the dust or dirt on the surface that sits on the seal of a heat exchanger box smaller box 1...