How the system functions
System Function as applied in all GenPure systems
Tap water that has been pretreated upstream by reverse osmosis, ion exchange or distillation flows
through a Pressure regulator and into the ultrapure water system, where the conductivity is monitored.
A pump directs this feedwater through UV-photooxidation (only possible in UV lamp equipped
systems) and then through the ultrapure cartridge. From there the water flows through an
ultrafiltration module (only possible in UF equipped systems). Then follows a permanent definition of
conductivity measured by a special conductivity measuring cell equipped with temperature
compensation. When ultrapure water is dispensed from the system, it flows through a a end filter
before reaching the point of use. During Interval operation, the water in the system is circulated in an
internal circuit at regular intervals.
Systems with UV-TOC, UV-TOC/UF
Tap water that has been pretreated upstream by reverse osmosis, ion exchange or distillation passes
through a Pressure regulator and into the ultrapure water system, where the conductivity is monitored.
A pump directs this feedwater through UV-photooxidation, which follows a conductivity measurement
to determine the TOC value. Then follows an ultrapure cartridge and an ultrafiltration module (only
with UV-TOC/UF), and the conductivity is then permanently measured by a special measuring cell
(with temperature compensation). When ultrapure water is taken from the system, it flows through a
final filter before reaching the dispensing outlet. During Interval operation, the water in the system is
recirculated in an internal circuit at regular intervals.
The TOC value is calculated by taking the difference between the values measured by the measuring
cells QIA300 and QI302. The measurement range is 0 - 30 ppb. When this range is exceeded, the
number 99 is shown in the display instead of the measured value.
In Stand-by operation, “___” is shown.
Содержание Barnstead GenPure
Страница 10: ...Contents 4 GenPure Thermo Scientific...
Страница 16: ...2 Safety precautions 10 GenPure Thermo Scientific...
Страница 22: ...4 Intended Use 16 GenPure Thermo Scientific...
Страница 28: ...6 The Installation Area 22 GenPure Thermo Scientific...
Страница 38: ...7 Installation Installation examples 32 GenPure Thermo Scientific...
Страница 40: ...8 Flow charts 34 GenPure Thermo Scientific...
Страница 42: ...9 How the system functions 36 GenPure Thermo Scientific...
Страница 48: ...11 Operating elements Flow chart of menu system control 42 GenPure Thermo Scientific...
Страница 66: ...12 System control GenPure Printer output 60 GenPure Thermo Scientific...
Страница 84: ...13 Maintenance Change and autoclave the Final filter 78 GenPure Thermo Scientific...
Страница 86: ...14 Waste disposal 78 GenPure Thermo Scientific...
Страница 90: ...15 Trouble shooting 82 GenPure Thermo Scientific...
Страница 91: ...Thermo Scientific GenPure 83 16 Replacement parts 10 13 11 4 3 6 5 7 2 9 14 8 1 12 16...
Страница 94: ...17 Consumable materials 86 GenPure Thermo Scientific...
Страница 96: ...18 Accessories 88 GenPure Thermo Scientific...
Страница 97: ...Thermo Scientific GenPure 89 19 Terminal assignments...
Страница 98: ...19 Terminal assignments 90 GenPure Thermo Scientific...
Страница 100: ...20 Maintenance records 92 GenPure Thermo Scientific...
Страница 105: ...Thermo Scientific GenPure 97 I ndex...