TK 61555-2-MM-EN
23
U
US
SB
B P
Po
orrtt:: A Universal Serial Bus (USB) port is provided on all units. If installed, it is located next
to the HMI. Standard USB flash drives that have been programmed with WinTrac can be used.
Use of a flash drive eliminates the need for an on-site computer and does not require cables.
IIm
mp
po
orrtta
an
ntt:: The flash drive must be properly configured and the desired features must be
enabled using WinTrac software.
Using a properly configured and enabled flash drive, the following functions may be available:
•
Download the ServiceWatch Data Logger
•
Download the CargoWatch Data Logger
•
Flash load Base Controller Software
•
Flash load HMI Control Panel Software
•
Send OptiSet Plus Files
•
Retrieve OptiSet Plus Files
C
Ca
arrg
go
oW
Wa
attcch
h P
Po
orrtt:: The CargoWatch port is used to download the CargoWatch Data Logger and
to flash load software to the HMI Control Panel. It is located on the Control Panel.
S
Se
errv
viicce
eW
Wa
attcch
h P
Po
orrtt:: The ServiceWatch port is used to download the ServiceWatch data logger
and to flash load software to the Base Controller.
P
Prriin
ntte
err P
Po
orrtt:: This port is used to print trip records from the CargoWatch Data Logger.
TK BlueBox
Beginning in 2017, the TK BlueBox communication device is fitted as standard on new SLXi
Series units and is also available as an option on certain other units. The TK BlueBox offers real-
time information and two-way communication.
A Maintenance Menu feature called Telematics Status is available that allows the user to check
for possible telematics status alarms. Telematics status alarms differ from standard unit alarms;
they do not appear as alarms on the HMI main screen if there is an issue with the TK BlueBox.
The user is required to access the Maintenance Menu and select Telematics Status to determine
if status alarms are activated.
The status alarms are listed below. Refer to the TK BlueBox Diagnostic Manual (TK 56391) for
complete information and diagnostic procedures.
T1
SIM Not Inserted
T8
Data Delayed to TracKing
™
T2
Check SIM PIN
T9
CAN Communication Issue
T3
Check APN Configuration
T10
Check iBox
™
Third Party
T4
Check GSM Antenna
T11
iBox System Issue
T5
No GSM Coverage
T12
Check Backup Battery
T6
Check GPS Antenna
TT99
Telematics System Issue
T7
No GPS Fix
OptiSet
™
™
The OptiSet
™
Temperature Management System allows up to ten different temperature ranges
to be defined and tailored for maximum operating efficiency, as determined by customer load
requirements. The term “OptiSet” refers to both the programmable ranges and the features that
can be tailored. OptiSet is programmed using the HMI Control Panel keypad.
Sequence of Operation
When the Microprocessor On/Off switch is turned on and Controller ON key is pressed, the LCD
display is illuminated and shows the setpoint and the return air temperature. If the CYCLE-
SENTRY mode has been selected, the unit will start and stop automatically. If the Continuous
mode has been selected, the unit will start and run automatically.