TK 61555-2-MM-EN
111
Pilot Solenoid
Removal
1.
Recover the refrigerant charge.
2.
Disconnect the wires and remove the coil from the valve.
3.
Unsolder the refrigeration lines.
4.
Remove the mounting bolts and remove the valve.
Installation
1.
Remove the coil from the valve.
2.
Place the valve in the unit and install the mounting bolts. The arrow on the valve indicates
the direction of flow through the valve. Verify that the arrow points in the proper direction.
3.
Solder the refrigeration lines to the valve.
4.
Install the coil and connect the wires.
5.
Pressurize the refrigeration system and test for leaks. If no leaks are found, evacuate the
system.
6.
Recharge the unit with the proper refrigerant and check the compressor oil.
Suction Vibrasorber
N
No
otte
e:: If there ia a possibility that the unit has been in a vacuum owing to a leak to the
vibraabsorber, the refrigerant must be recovered.
Removal
1.
Pump down the low side and equalize pressure to slightly positive.
2.
Unsolder the suction vibrasorber from the suction service valve.
N
NO
OT
TIIC
CE
E
E
Eq
qu
uiip
pm
me
en
ntt D
Da
am
ma
ag
ge
e!!
U
Usse
e a
a h
he
ea
att ssiin
nkk o
orr w
wrra
ap
p E
ET
TV
V w
wiitth
h w
we
ett rra
ag
gss tto
o p
prre
ev
ve
en
ntt d
da
am
ma
ag
giin
ng
g tth
he
e E
ET
TV
V..
3.
Unsolder the other end of the suction vibrasorber from the ETV and remove the vibrasorber
from the unit.
Installation
1.
Prepare the suction vibrasorber and tube fittings for soldering by cleaning the thoroughly.
N
NO
OT
TIIC
CE
E
E
Eq
qu
uiip
pm
me
en
ntt D
Da
am
ma
ag
ge
e!!
U
Usse
e a
a h
he
ea
att ssiin
nkk o
orr w
wrra
ap
p v
viib
brra
asso
orrb
be
err w
wiitth
h w
we
ett rra
ag
gss tto
o p
prre
ev
ve
en
ntt d
da
am
ma
ag
giin
ng
g tth
he
e v
viib
brra
asso
orrb
be
err..
2.
Solder the vibrasorber to the suction service valve.
N
NO
OT
TIIC
CE
E
E
Eq
qu
uiip
pm
me
en
ntt D
Da
am
ma
ag
ge
e!!
U
Usse
e a
a h
he
ea
att ssiin
nkk o
orr w
wrra
ap
p E
ET
TV
V w
wiitth
h w
we
ett rra
ag
gss tto
o p
prre
ev
ve
en
ntt d
da
am
ma
ag
giin
ng
g tth
he
e E
ET
TV
V..
3.
Solder the other end of the suction vibrasorber to the ETV.
4.
Pressurize the low side and check for leaks. If no leaks are found, evacuate the system.
5.
Open the refrigeration valves and place the unit in operation.