124
TK 61555-2-MM-EN
1.
Remove Bolts from Damper Door Shaft
2.
Remove Bolts from Damper Gear Motor Shaft
3.
Remove Screws from Damper Gear Motor (one not
shown)
3. Remove the two bolts that attach the damper door to the damper gear motor shaft and
remove damper door.
4. Disconnect the damper gear motor harness from the main harness.
5. Remove the three screws that attach the damper gear motor to the evaporator blower
housing and remove the damper gear motor. These screws are located on the inside of the
evaporator blower housing.
6. Place the new damper gear motor in position and fasten it to the evaporator blower housing
with the three screws.
7. Reconnect the damper gear motor harness to the main harness.
8. Place the damper door in position and fasten it to the damper gear motor shaft with the two
bolts.
9. Fasten the damper door to the damper door shaft with the two bolts.
10. Replace the evaporator access panels that were removed to access the damper gear motor
and damper door.
Condenser and Evaporator Fan Location
When mounting the condenser or evaporator fan and hub assembly on the fanshaft, the blowers
and inlet orifices must be properly aligned for proper air flow and to prevent damage to the
blower.
Condenser Inlet Orifice Alignment
1. Loosen the condenser inlet orifice on the condenser coil bulkhead.
2. Center the inlet orifice in the condenser blower and tighten the inlet orifice mounting
hardware to hold the inlet orifice in this position.
3. Check the radial clearance of the blower by passing a 2.3 mm (0.09 in.) gauge wire completely
around the circumference of the condenser orifice and the condenser blower.