TK 61555-2-MM-EN
121
Figure 98.
Coil after Wiping Right Hand Side with Cloth
Figure 99.
Source Angle for Cleaning with Air or Water
Defrost Drains
Clean the defrost drains during scheduled maintenance inspections to verify the lines remain
open.
Unit Installation
All nuts that hold the unit to the trailer are accessible using an impact wrench with a 25 cm (10
inch) extension, ball-type swivel, and a deep-well socket.
N
No
otte
e:: The nuts for mounting the unit should be elastic stop nuts (Nylock type).
Defrost Damper
This unit uses a defrost damper that is actuated by a damper gear motor. The damper door is
attached directly to the damper gear motor shaft to simplify the linkage.