Electrical Maintenance (Rev. 04/03)
59
Current Relay
Check the voltage between T1 and T2 at terminal 1 of the
current relay and between T1 and T2A at terminal 3 of the
current relay. If there is voltage between T1 and T2, but not T1
and T2A, the control coil is open. / Replace the current relay.
Check the voltage on 7EB at terminal 2 of the current relay with
unit control voltage (12 to 14 volts dc) present at 7EA on
terminal 4 of the current relay and the current relay energized
(current in T2A above 30 amps). If there is no control voltage or
low control voltage on 7EB when the current relay is energized,
the current relay is defective. / Replace the current relay.
Motor Start Relay
Check the voltage on 7EC at the motor start relay with unit
control voltage (12 to 14 volts dc) present on 7EA and 7EB at
the motor start relay. If there is no control voltage or low control
voltage on 7EC, the motor start relay is defective. / Replace the
motor start relay.
Motor Start Contactor
Line voltage must be present between T1 and T3 and T1 and
T31 at the motor start contactor. If not, check T3 from the motor
contactor to the start contactor. / Repair T3 as necessary. Check
the voltage between T1 and T3C and T1 and T3D with control
voltage present on 7EC at the motor start contactor. Line
voltage should be present. If no voltage is present, the control
coil of the start contactor is defective. If low voltage is present,
the points are defective. / Repair or replace the contactor or
points as necessary.
PROBLEM/PROBABLE CAUSE
TEST/SOLUTION
Содержание KD-II SR
Страница 4: ......
Страница 8: ......
Страница 13: ...Safety Precautions Rev 04 03 v AEA40...
Страница 14: ...Safety Precautions Rev 04 03 vi AEA38...
Страница 33: ...Unit Description Rev 04 03 19 1 Evaporator 2 Access Door Rear View Curbside KD II SR 1 2 AEA38...
Страница 37: ...Unit Description Rev 04 03 23 Power Receptacle Box KD II SR 50 AEA42...
Страница 38: ...Unit Description Rev 04 03 24 1 Keypad 2 LED Display THERMOGUARD Remote Control Panel AEA43 1 2...
Страница 42: ...P T System Description Rev 04 03 28 High Voltage Tray No Options High Voltage Tray with Phase Correction...
Страница 44: ...P T System Description Rev 04 03 30 High Voltage Tray with Single Phase Power and Electric Heater...
Страница 58: ...Remote Control Panel Features Rev 04 03 44...
Страница 112: ...Refrigeration Maintenance Rev 04 03 98...
Страница 120: ...106...
Страница 146: ...132...
Страница 156: ...142...
Страница 162: ...148...
Страница 170: ...156...
Страница 172: ...158...
Страница 173: ...159 KD II 30 Schematic Diagram Page 1 of 2...
Страница 174: ...160 KD II 30 Schematic Diagram Page 2 of 2...
Страница 175: ...161 KD II 30 Wiring Diagram Page 1 of 2...
Страница 176: ...162 KD II 30 Wiring Diagram Page 2 of 2...
Страница 177: ...163 KD II 50 Schematic Diagram Page 1 of 2...
Страница 178: ...164 KD II 50 Schematic Diagram Page 2 of 2...
Страница 179: ...165 KD II 50 Wiring Diagram Page 1 of 2...
Страница 180: ...166 KD II 50 Wiring Diagram Page 2 of 2...
Страница 181: ...167 KD II 50 SR 230 1 60 Wiring Diagram Page 1 of 2...
Страница 182: ...168 KD II 50 SR 230 1 60 Wiring Diagram Page 2 of 2...