MP-3000a Controller
95
Set Log Time
With the unit On/Off switch ON and the LCD display show-
ing the standard display (setpoint):
1. Press the F3 key to enter the Main Menu.
2. Press F2 key to scroll through Main Menu
until “DATA-LOGGER” appears in LCD
display.
3. Press F4 key to access the Datalogger menu.
“Inspect Temp Log” appears in the LCD
display.
4. Press F2 or F3 key to scroll through submenu
until “Set Log Time” appears in LCD display.
5. Press F4 key to enter Temp Log. LCD display
shows the current Log Time interval.
6. To enter a new log interval, press F4 key again
with cursor in Log Time menu line. Arrow
appears in menu line.
7. Press F3 key to scroll through a list of log time
intervals:
- 1 Minute*
- 1/2 Hour
- 1 Hour
- 2 Hour
- 4 Hour
NOTE: *When a 1 Minute Log Test is selected,
the datalogger records unit operating
information every minute for 72 minutes.
During the 1 Minute Log Test, only the 1 Minute
Log can be retrieved for viewing. The
Temperature Log and Event Logs can not be
viewed. When the 1 Minute Log Test is complete,
the 1 minute log is cleared from the datalogger
memory. The data-logger resumes logging using
the previous log time setting.
8. When the correct log time appears in the menu
line, press and hold F4 key until cursor stops
flashing. The new Log Time appears in the
display.
9. Press ESC key to exit the Temp Log.
Set a Trip Start
With the unit On/Off switch ON and the LCD
display showing the standard display (setpoint):
1. Press the F3 key to enter the Main Menu.
2. Press F2 key to scroll through Main Menu
until “DATA-LOGGER” appears in LCD
display.
3. Press F4 key to access the Datalogger menu.
“Inspect Temp Log” appears in the LCD
display.
4. Press F2 or F3 key to scroll through submenu
until “Activate Tripstart” appears in LCD
display.
5. Press F4 key to enter Tripstart function. The
date and time of the last trip start appears in
the screen.
6. Press F4 key again to enter a new start of trip
date and time in the log.
NOTE: When a PTI Test is completed, the
controller automatically enters a Tripstart in
the log.
7. Press ESC key to exit the Datalogger menu.
Inspect PTI Log
With the unit On/Off switch ON and the LCD
display showing the standard display (setpoint):
1. Press the F3 key to enter the Main Menu.
2. Press F2 key to scroll through Main Menu
until “DATA-LOGGER” appears in LCD
display.
3. Press F4 key to access the Datalogger menu.
“Inspect Temp Log” appears in the LCD
display.
4. Press F2 or F3 key to scroll through submenu
until “Inspect PTI Log” appears in LCD
display.
5. Press F4 key to enter PTI Log. LCD display
shows the Start Time and PTI test results of
the most recent PTI log.
•
To scroll through additional test results in
the log, press F3 key.
Содержание CRR-40 119
Страница 4: ......
Страница 16: ...Safety Precautions 16...
Страница 18: ...Service Guide 18...
Страница 20: ...Model Features 20...
Страница 32: ...Specifications 32...
Страница 120: ...MP 3000a Controller 120...
Страница 160: ...Wiring and Schematic Diagrams Index 160...
Страница 161: ...161 MPC2000 Wiring Schematic...
Страница 162: ...162 MPC2000 High Voltage Wiring Diagram...
Страница 163: ...163 MPC2000 Low Voltage Wiring Diagram...
Страница 164: ...164 MPC2000 WCC Wiring Schematic...