MP-3000a Controller
87
Viewing the Misc. Functions Menu
With the unit On/Off switch ON and the LCD
display showing the standard display (setpoint):
1. Press F3 key to enter the menu list. Press F2
key to scroll through Main Menu until “MISC.
FUNCTIONS” appears in LCD display.
2. Press F4 key to access the Misc. Functions
menu. The first command in the submenu
appears in the LCD display: Date Time.
3. Press F2 or F3 key to scroll to the desired
function:
•
Date Time
•
Run Time
•
Program Version
•
Cargo Data
•
C/F Mode
4. Press F4 key to access the function selected.
Setting the Date and Time
1. Press F3 key to enter the menu list. Press F2
key to scroll
to “MISC. FUNCTIONS”.
2. Press F4 key to access the Misc. Functions
menu. “Date Time” appears in the LCD
display.
3. Press F4 key to access the Date Time screen.
Date Time screen appears with cursor in the
Time menu line. Display shows time in
“HH.MM.SS” where H = hour, M = minute
and S = second.
4. To enter a new time, press F4 key with cursor
in Time menu line. An Enter Arrow appears in
the menu line and the previous time
disappears.
5. Enter new time in “HH.MM.SS” format.
Decimal points must be included in the entry
between the hour, minute and second.
NOTE: To scroll backward in the Time or
Date menu line, press and hold the F4 key,
then press F3 key. Press F1 key to return
keyboard to “numerical” entry before typing
again.
6. With the correct time entered in the menu line,
press F4 key. Then press EXIT key to enter
time in controller memory. Cursor stops
blinking and new time appears in display.
7. To enter a new date, press F3 key to move
cursor to Date menu line. Display shows date
in and date in “YY.MM.DD” where Y = year,
M = month and D = day.
8. Press F4 key with cursor in Date menu line.
An Enter Arrow appears in the menu line and
the previous date disappears.
9. Enter new date in “YY.MM.DD” where Y =
year, M = month and D = day. Decimal points
must be included in the entry between the
year, month and day.
10. With the correct date entered in the menu line,
press F4 key. Then press EXIT key to enter
date in controller memory. Cursor stops
blinking and new date appears in the display.
11. Press ESC key to exit the Date Time screen.
Viewing or Setting Run Time
1. Press F3 key to enter the menu list. Press F2
key to scroll
to “MISC. FUNCTIONS”.
2. Press F4 key to access the Misc. Functions
menu. “Date Time” appears in the LCD
display. Press F2 key to scroll to “RUN
TIME”.
3. Press F4 key to access the Run Time screen.
The Run Time screen appears with cursor in
HEAT menu line.
4. Press F3 key to scroll cursor down through
cargo data list:
- HEAT
- COMPRESSOR
- EVAPORATOR HIGH
- EVAPORATOR LOW
- CONDENSER
- TOTAL
Содержание CRR-40 119
Страница 4: ......
Страница 16: ...Safety Precautions 16...
Страница 18: ...Service Guide 18...
Страница 20: ...Model Features 20...
Страница 32: ...Specifications 32...
Страница 120: ...MP 3000a Controller 120...
Страница 160: ...Wiring and Schematic Diagrams Index 160...
Страница 161: ...161 MPC2000 Wiring Schematic...
Страница 162: ...162 MPC2000 High Voltage Wiring Diagram...
Страница 163: ...163 MPC2000 Low Voltage Wiring Diagram...
Страница 164: ...164 MPC2000 WCC Wiring Schematic...