![Thermo King CRR-40 119 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/thermo-king/crr-40-119/crr-40-119_manual_1104388012.webp)
Safety Precautions
12
Refrigerant Oil
Observe the following precautions when working
with or around refrigerant oil:
•
Do not allow refrigerant oil to contact your
eyes.
•
Do not allow prolonged or repeated contact
with skin or clothing.
•
To prevent irritation, you should wash
thoroughly immediately after handling
refrigerant oil. Rubber gloves are
recommended when handling Polyester based
refrigerant oil.
First Aid:
Eyes:
Immediately flush eyes with large amounts
of water for at least 15 minutes while holding the
eyelids open. Get prompt medical attention.
Skin:
Remove contaminated clothing. Wash
thoroughly with soap and water. Get medical
attention if irritation persists.
Inhalation:
Move victim to fresh air and restore
breathing if necessary. Stay with victim until
arrival of emergency personnel.
Ingestion:
Do not induce vomiting. Contact a
local poison control center or physician
immediately.
Electrical
High Voltage
When servicing or repairing a refrigeration unit,
the possibility of serious or even fatal injury from
electrical shock exists. Extreme care must be used
when working with a refrigeration unit that is
connected to a source of operating power, even if
the unit is not running. Lethal voltage potentials
can exist at the unit power cord, inside the control
box, inside any high voltage junction box, at the
motors and within the wiring harnesses.
Precautions
1. Be certain the unit
O
N
/O
FF
switch is turned
Off before connecting or disconnecting the
unit power plug. Never attempt to stop the unit
by disconnecting the power plug.
2. Be certain the unit power plug is clean and dry
before connecting it to a power source.
3. Use tools with insulated handles that are in
good condition. Never hold metal tools in
your hand if exposed, energized conductors
are within reach.
4. Do not make any rapid moves when working
on high voltage circuits. If a tool or other
object falls, do not attempt to grab it. People
do not contact high voltage wires on purpose.
It occurs from an unplanned movement.
5. Treat all wires and connections as high
voltage until a meter and wiring diagram show
otherwise.
6. Never work alone on high voltage circuits on
the refrigeration unit. Another person should
always be standing by in the event of an
accident to shut off the refrigeration unit and
to aid a victim.
7. Have electrically insulated gloves, cable
cutters and safety glasses available in the
immediate vicinity in the event of an accident.
Содержание CRR-40 119
Страница 4: ......
Страница 16: ...Safety Precautions 16...
Страница 18: ...Service Guide 18...
Страница 20: ...Model Features 20...
Страница 32: ...Specifications 32...
Страница 120: ...MP 3000a Controller 120...
Страница 160: ...Wiring and Schematic Diagrams Index 160...
Страница 161: ...161 MPC2000 Wiring Schematic...
Страница 162: ...162 MPC2000 High Voltage Wiring Diagram...
Страница 163: ...163 MPC2000 Low Voltage Wiring Diagram...
Страница 164: ...164 MPC2000 WCC Wiring Schematic...