MP-3000a Controller
66
Displaying Alternate
Fahrenheit (F) or Celsius (C)
Temperatures
The controller can display temperatures in
Fahrenheit or Celsius. With the unit On/Off
switch ON and the controller showing a standard
LED Display:
1. Press and hold the C/F key. The controller will
show both the LED and LCD display
temperatures in the alternate temperature scale
(Fahrenheit or Celsius) as long as the C/F key
is depressed.
2. The display then returns to the original display
when the C/F key is released.
NOTE: To change the default temperature
unit display, press and hold the C/F key, then
press the SET-POINT key for 1 second.
Navigating the Controller Menu
NOTE: To view the controller’s menu or
download data when external power is
disconnected from the unit, press a special key:
C/F key, SUP/RET key, DEFROST key or
SETPOINT key. The controller LCD display will
appear using 12 Vdc battery power.
The Main Menu is divided into eight major
menus:
•
Setpoint
•
Data
•
Alarm List
•
Commands
•
Misc. Functions
•
Configuration
•
Datalogger
•
Remote Monitoring (RMM) State
Moving through these eight menus and their
submenus and entering commands requires the
use of four text keys:
F1 key: Press the F1 key each
time you want to exit a submenu.
or
F2 or F3 key: Press the F3 key to
enter the Main Menu. Then
pressure the F2 or F3 key each
time you want to scroll up or
down to view another item in a
menu or submenu; or scroll
forward or backward in a menu
line.
F4 key: Press the F4 key to enter a new
menu or sub-menu; to access a menu line
to enter information; or to load a
command or value.
General Operating Tips
•
Quickly change display temperature units
between C and F: Press and hold the C/F key,
then press the SETPOINT key for 1 second.
•
Increase display time for current LCD data
screen: Press the “5” key to increase display
time by 5 minutes. Maximum display time is
30 minutes for data screens and 100 minutes
for manual tests.
•
Slowly cool (initial pull-down) a warm load:
Set power management to 13 amps.
•
Password for Configuration changes is “A”:
Press F2 key, “A” key, F4 key and then EXIT
key.
Содержание CRR-40 119
Страница 4: ......
Страница 16: ...Safety Precautions 16...
Страница 18: ...Service Guide 18...
Страница 20: ...Model Features 20...
Страница 32: ...Specifications 32...
Страница 120: ...MP 3000a Controller 120...
Страница 160: ...Wiring and Schematic Diagrams Index 160...
Страница 161: ...161 MPC2000 Wiring Schematic...
Страница 162: ...162 MPC2000 High Voltage Wiring Diagram...
Страница 163: ...163 MPC2000 Low Voltage Wiring Diagram...
Страница 164: ...164 MPC2000 WCC Wiring Schematic...