MP-3000a Controller
114
Code
Description
Corrective Action
25
Evaporator Temperature Test Error (Check
Alarm)
• Occurs during Pretrip (PTI) test only.
• Evaporator coil temperature too high with no
evaporator fans running (above about -15 C [+5
F]).
• Indicates
• Evaporator coil sensor is not in contact with
evaporator coil
• Return and evaporator coil sensor
connections are interchanged
• Expansion valve does not open enough or
opens too much.
• Check evaporator coil sensor location.
• Check evaporator coil sensor and return air
sensor connections.
• Check expansion valve superheat setting.
27
Heat Capacity Test Error (Check Alarm)
• Occurs during Pretrip (PTI) test only.
• Difference between supply and return air
temperature too small with high speed
evaporator fans (less than 0.4 C [0.7F]}.
• Indicates:
• Incorrect location of supply or return air sensor
• Air leakage at supply, return or evaporator coil
sensor cable
• Defective supply or return air sensor
• Interchanged sensor connections
• Defective heater elements
• Incorrect evaporator fan rotation or high speed
operation
• Container/side panels, defective, damaged or
leaking
• Enter Manual Function Test and start evaporator
fans on HIGH speed. Then select Sensor
Checks test and operates fans 2 to 5 minutes.
Check supply, return and evaporator coil
(defrost) sensor temperatures. Sensor readings
should be the same (evaporator coil may be 0.5
C [1.0 F] lower due to fan motor heat).
NOTE: this sensor check does not detect
air leakage around the sensor cables
• Open evaporator door and inspect evaporator
fan rotation. make sure fans are rotating correctly
on high speed.
• Check the sensor connections.
32
Condenser Temperature Sensor Open Circuit
(Check Alarm)
• Sensor circuit resistance higher than 100,000
ohms.
• Temperature below -70 C (-94 F).
• Indicates
• Open circuit to sensor
• Defective or wrong sensor
• Defective relay board
• Defective cable no.1
• Defective controller
• Check sensor resistance between pins 7 and 8
on plug J15. Resistance must be 2,000 ohms at
25 C (77 F).
• Check cable No. 1 between controller and relay
board.
Содержание CRR-40 119
Страница 4: ......
Страница 16: ...Safety Precautions 16...
Страница 18: ...Service Guide 18...
Страница 20: ...Model Features 20...
Страница 32: ...Specifications 32...
Страница 120: ...MP 3000a Controller 120...
Страница 160: ...Wiring and Schematic Diagrams Index 160...
Страница 161: ...161 MPC2000 Wiring Schematic...
Страница 162: ...162 MPC2000 High Voltage Wiring Diagram...
Страница 163: ...163 MPC2000 Low Voltage Wiring Diagram...
Страница 164: ...164 MPC2000 WCC Wiring Schematic...