MP-3000a Controller
68
Figure 16: Setpoint Menu Screen Flow Diagram
Changing the Humidity Mode
Setting
1. Press the SETPOINT key. The SETPOINT
menu appears with the cursor in the “TEMP
SETP” line.
2. Press F2 key to scroll to “HUM CONTROL”
line.
3. To change the mode setting, press F4 key.
Cursor moves to end of menu line and flashes.
4. Press F2 key to toggle between OFF and ON.
5. With the desired state in the menu line, press
and hold F4 key until cursor stops flashing.
New mode setting appears in display.
6. Press ESC key to exit the SETPOINT screen.
Changing the Humidity Setpoint
1. Press the SETPOINT key. The SETPOINT
menu appears with the cursor in the “TEMP
SETP” line.
2. Press F2 key to scroll to “HUM SETP” line.
3. To enter a new setpoint, press the F4 key. An
Enter Arrow appears in the menu line and the
current setpoint disappears.
4. Enter (type) the new setpoint in the LCD
display using the general purpose keypad. The
cursor moves to the right of the screen as each
key entry is acknowledged and displayed.
NOTE: Always check that the setpoint
entered in the LCD display is correct before
proceeding.
5. Press and hold the F4 key until the cursor
stops flashing. The new setpoint is recorded in
the controller and appears in the LCD display.
6. Press ESC key to exit the SETPOINT screen.
Data Menu
NOTE: Information can ONLY be displayed
using the Data menu. Items can NOT be
changed.
The Data menu displays general unit operating
information including sensor temperatures, unit
electrical data, etc.
Viewing the Data Menu
With the unit On/Off switch ON and the LCD
display showing the standard display (setpoint):
1. Press F4 key to directly enter the Data menu.
Menu items appear in LCD display.
Note: All screens are not present on all units.
The screens that display on the controller are
determined by the Controller Software setting
and the options installed on the unit.
Setpoint Menu
Enter a Temperature or
Humidity Setpoint
Activate Humidity
Control or Economy
Mode
OPTI -SET
TEMP. SETP.
BULB MODE
EVAP FAN SPD.
DEFROST TRM.
ECONOMY MODE
HUM CONTROL
HUM SETP.
AFAM
AFAM DELAY
AFAM RATE
CO2 MAX.
• Press F4 key.
• Type the new setpoint.
• Press and hold F4 key until cursor
stops flashing.
• Press F4 key.
• Press F2 key to toggle setting
between off and on.
• Press and hold F4 key until
cursor stops flashing.
Содержание CRR-40 119
Страница 4: ......
Страница 16: ...Safety Precautions 16...
Страница 18: ...Service Guide 18...
Страница 20: ...Model Features 20...
Страница 32: ...Specifications 32...
Страница 120: ...MP 3000a Controller 120...
Страница 160: ...Wiring and Schematic Diagrams Index 160...
Страница 161: ...161 MPC2000 Wiring Schematic...
Страница 162: ...162 MPC2000 High Voltage Wiring Diagram...
Страница 163: ...163 MPC2000 Low Voltage Wiring Diagram...
Страница 164: ...164 MPC2000 WCC Wiring Schematic...