MPC2000ID Controller Menu Flow Diagram
Standard Display
MAIN
MENU
— DATA
— ALARMS
— COMMANDS
— MISC FUNCTIONS
— CONFIGURATION
— DATALOGGER
— RMM STATE
NOTE: The screens that display on the controller
are determined by the Unit Configuration setting.
All screens are NOT
present on all units.
Keypad Operating Tips
Text Input:
Use F1, F2, F3 and F4 keys to enter text in information screens:
• To enter a number: Press the F1 key and the desired number key.
• To enter 1st letter on a key: Press the F2 key, the desired letter key.
• To enter 2nd letter on a key: Press the F3 key, the desired letter key.
• To enter 3rd letter on a key: Press the F4 key, the desired letter key.
NOTE: When a function key (F1, F2, F3 or F4) is pressed to enter text,
the keypad remains on that “character level” until another function key
is pressed.
To Enter a Controller Menu or Use Special Function Key:
• Press F4 key to directly enter the Data menu.
• Press F2 key to directly enter the Alarms menu.
• Press F3 key to directly enter the Main Menu.
• Press SETPOINT key to enter Setpoint menu.
• Press
C/F key to view alternate temperature scale in LED display.
• Press SUP/RET key to view alternate sensor temperature in LED display.
• Press DEFROST key to initiate a manual defrost. Evaporator coil tempera-
ture must be below 10 C (50 F).
To Enter a Submenu, a Command or a New Value in a Text Screen:
• Press F4 key.
To Scroll in a Menu or a Text Line:
• Press F2 key to scroll up or forward.
• Press F3 key to scroll down or backward.
To Exit a Menu or Text Line:
• Press F1 (ESC) key.
Special Function Keys:
• Press
C/F key to view alternate temperature scale in LED display.
• Press DEFROST key to initiate a manual defrost. Evaporator coil tempera-
ture must be below 10 C (50 F).
• Press SUP/RET key to view alternate return/supply- sensor temperature in
LED display.
To Lock a LCD Data Screen Display:
• Each time the “5” key is pressed, the display time of the current LCD screen
increases by 5 minutes. Maximum display time is 30 minutes for data
screens and 100 minutes for manual tests. Press F1 (ESC) key to exit dis-
play.
Setpoint Menu
— Setpoint Temperature
— Humidity Control
— Humidity Setpoint
— Economy Mode
RMM Status
Display shows current
status:
• Offline
• Zombie
• On-line
Data Menu
— Supply Air Temp, RH
— Return Air Temp
— Defrost (Evap Coil) Temp
— Condenser Coil Temp
— KVQ Valve Setting
— Ambient Temp
— High Pressure
— High Pressure Temp
— Relative Humidity
— Battery Voltage
— Voltage Average
— Voltage 1
—
Voltage 2
—
Voltage 3
— Frequency
— Zero Current
— Current Phase 1
— Current Phase 2
— Current Phase 3
— Supply Air Temp, LH
Commands Menu
— Defrost
— Function Test
— PTI (Pretrip) Test
— Manual Function Test
— Power Management
Alarms Menu
• View and write down all alarm
codes.
• Press F2 key to view the next
alarm code.
• Clear alarm code by correcting
problem and acknowledging
the alarm.
• To acknowledge an alarm,
press F4 key with alarm code in
display.
To Activate a Command
• Press F4 key to start a:
- Manual Defrost
- Function Test
- PTI (Pretrip) Test
Manual Function Test
Submenu
• First Component Test appears
in display.
• Press F2 or F3 key to scroll to
to the desired component:
- Condenser Fan
- Compressor
- Capacity 25%
- Capacity 50%
- Capacity 100%
- Injection Valve
- Dehumidify Valve
- Evaporator High
- Evaporator Low
- Heat
- Zero Current
- Sensor Checks
• Press F4 key to start and stop
test (toggle component display
between ON and OFF).
• More than one component
can be turned ON at a time to
perform a functional test of
the unit.
Power Management Submenu
• Current Power Limit and Power
Time appear in display.
• Press F3 key to scroll to
desired function.
• Press F4 key.
- Power Limit: Press F2 or F3
key to scroll to new setting.
- Power Time: Type the new
time in hours.
• Press and hold F4 key until
cursor stops flashing.
Misc. Functions Submenu
• Current function setting appears
in display.
• Press F3 key to scroll to desired
function.
• Press F4 key to change a
setting.
• Type new value; or press F3
key to toggle value to desired
setting.
• Press and hold F4 key until
cursor stops flashing.
Configuration Submenu
• Current function setting
appears in display.
• Press F4 key to change a
setting.
• Press F2 key, “A” key (pass-
word), F4 key and EXIT key.
• Type new value; or press F3
key to toggle value to desired
setting.
• Press and hold F4 key until
cursor stops flashing.
Datalogger Submenu
• First function screen appears:
- Inspect Temp Log: Press F4
key to view next screen.
Press F3 key to scroll through
previous logs of sensors.
- Inspect Event Log: Press F3
key to scroll through previous
event logs.
- Set Log Time: Press F3 key to
scroll through log interval list.
Press and hold F4 key until
cursor stops flashing.
- Activate Tripstart: Press F4
key to enter trip start marker.
- Inspect PTI Log: Press F3 key
through test result screens.
Enter a Temperature or
Humidity Setpoint
• Press F4 key.
• Type the new setpoint.
• Press and hold F4 key until
cursor stops flashing.
Activate Humidity Control or
Economy Mode
• Press F4 key.
• Press F2 key to toggle setting
between OFF and ON.
• Press and hold F4 key until
cursor stops flashing.
Datalogger Menu
— Inspect Temp Log
— Inspect Event Log
— Set Log Time
— Activate Tripstart
— Inspect PTI Log
Configuration Menu
— In-Range
— Container ID
— Contrast
— Language
— Economy Max.
— Economy Min.
— Unit Type
— Reefer Type
— Zero Current
— Supply LH
Misc. Functions Menu
— Date Time
— C/F Mode
— Cargo Data
— Program Version
— Run Time
Содержание CRR-40 119
Страница 4: ......
Страница 16: ...Safety Precautions 16...
Страница 18: ...Service Guide 18...
Страница 20: ...Model Features 20...
Страница 32: ...Specifications 32...
Страница 120: ...MP 3000a Controller 120...
Страница 160: ...Wiring and Schematic Diagrams Index 160...
Страница 161: ...161 MPC2000 Wiring Schematic...
Страница 162: ...162 MPC2000 High Voltage Wiring Diagram...
Страница 163: ...163 MPC2000 Low Voltage Wiring Diagram...
Страница 164: ...164 MPC2000 WCC Wiring Schematic...