16
24
Thermal power (min/max)
kW
5 / 12
6,7 / 16
10 / 24
Thermal power of fluid (water) (min/max)
kW
4,1 / 9,7
5,4 / 12,9
8,1 / 19,4
Hourly fuel consumption (min/max)
kg/h
1,1 / 2,6
1,5 / 3,6
2,3 / 5,4
Efficiency
%
89
90
90
CO content (with 13% O2) min/max
%
0,02 / 0,0025
0,02 / 0,0025
0,02 / 0,003
Flue temperature (min/max)
°C
125 / 180
110 / 170
85 / 140
Minimum draught
Pa
Maximum power rating
W
Power rating at work
W
Supply voltage and frequency
V/Hz
Fuel tank capacity
kg
27
32
36
Expansion tank capacity
lt
Maximum working pressure
bar
Flow / Return (F / R )
R
Safety valve (SV)
R
External dimensions
H
mm
1050
1120
1180
H1
mm
H2
mm
H3
mm
W
mm
600
W1
mm
110
L
mm
610
D
mm
Fresh air intake diameter
mm
230/50
6
3/4"
Ø 50
M odel
HYDRA
Types
320
10
400
160
3
3/4"
Ø 80
560
540
80
250
50