The poorer the quality of the fuel, the more often the internal parts of the brazier and
combustion chamber must be cleaned.
The pellet used must comply with the features described by Standards:
EN PLUS - UNI EN 16961 - 2 class A1 or A2
Ö-NORM M 7135
DIN PLUS 51731
We recommend using pellets with a diameter of 6mm with its products.
Pellet storage
To guarantee combustion without problems, the pellets must be kept in a dry place.
Poor quality pellets or others that do not comply with that specified previously
compromises the operation of your product and can therefore render the warranty and
product liability null and void.
PRECAUTIONS REGARDING INSTALLATION
The product must be installed in a suitable place for it to be regularly opened and routine
maintenance to be performed. The site must be:
• Compliant for proper operation.
• Equipped with an adequate smoke expulsion system.
• Equipped with ventilation intake from outside.
• Equipped with 230V 50 Hz power supply with an EC compliant earth system.
The product must be connected to a chimney or an internal or external vertical duct that complies
with the regulations in force. The product must be positioned in such a way that the electrical
socket is accessible.
IMPORTANT!
The product must be connected to a chimney or a vertical duct that can expel the smoke at
the highest point of the building. In any case smoke derives from combustion of types of
wood and if it comes in contact with or close to walls, these can become dirty. Moreover,
utmost attention is required as they are almost invisible but very hot and can cause burns.
The holes of the external air inlet and the smoke outlet pipe must be drilled before positioning the
product.