Modulation Mode
The modulation range has been pre-set so that the system starts reducing to a lower power level
when the water temperature comes within 8°C of the set point.
Standby / Extinguishing / OFF
The system goes into STANDBY when the water in the buffer reaches its set temperature or the
water in the stove reaches its set temperature (whichever is sooner) and the system goes into an
extinguishing mode.
-The auger stops feeding pellets to the burner.
-The exhaust fan will run at full power until all light in the burner has extinguished and the
temperature in the flue has decreased to a safe temperature.
-Once the flame has been extinguished the system enters its Final Cleaning stage where the burner
cleaning takes place (the fan runs in its maximum to eliminate the dust in the fire pote).
The system will sit in standby until the water temperature decreases to a pre-determined amount
when it will restart again with the CHECK UP phase.
The system will go into the OFF state when the system gets a signal from a room thermostat or if the
system is turned off manually on the controller. The shutdown procedure is the same as STANDBY.
Once the extinguishing phase has been completed the stove will remain in the OFF state until a signal
is given to the stove to start.
Shutting the stove down (end of season)
At the end of season, before shutting down the stove, we recommend completely removing pellets
from the hopper with the use of a vacuum cleaner with an extension.
During periods of disuse, the stove must be unplugged and placed in a dry place
protected from the elements. For greater safety, especially if there are children around,
we recommend removing the supply cable from the rear of the stove.