APPENDIX
A-2
Manual 0-2957
APPENDIX 2: SEQUENCE OF OPERATION
(BLOCK DIAGRAM)
ACTION:
ON / OFF switch to ON
RESULT:
AC indicator ON.
Fan(s) ON.
GAS indicator ON
when input
pressure is adequate
for power supply operation.
Power circuit ready.
ACTION:
Protect eyes and activate torch.
RESULT:
Gas flows briefly, then stops.
Gas restarts.
DC indicator ON
Pilot arc established.
Art #A-03706
ACTION:
Unplug input
power cord or
open external
disconnect.
RESULT:
No power to system.
ACTION:
Connect work cable to workpiece.
Set output amperage.
RESULT:
System is ready
for operation.
ACTION:
RUN /
Rapid Auto Restart /
SET switch
to SET
RESULT:
Gas flows to set pressure.
ACTION:
RUN /
Rapid Auto Restart / SET
switch to RUN
(for most applications)
or to
Rapid Auto Restart
(for gouging, trimming,
or expanded metal
applications)
RESULT:
Gas flow stops.
ACTION:
Release torch trigger.
RESULT:
Main arc stops.
Gas flow stops after post - flow.
ACTION:
ON / OFF switch
to OFF
RESULT:
All indicators off.
Power supply fan(s) shuts off.
ACTION:
Close external
disconnect switch.
RESULT:
Power to system.
ACTION:
Torch moved within
transfer distance of workpiece.
RESULT:
Main arc transfers.
Pilot arc off.
PILOT ARC
ACTION:
Torch moved away from work (while
still activated).
RESULT:
Main arc stops.
Pilot arc automatically
restarts.
Содержание CUTMASTER 81
Страница 2: ......
Страница 4: ......
Страница 16: ...INTRODUCTION 2 2 Manual 0 2957 This Page Left Blank...
Страница 20: ...DESCRIPTION 3 4 Manual 0 2957 This Page Left Blank...
Страница 40: ...TROUBLESHOOTING 4 20 Manual 0 2957 This Page Left Blank...
Страница 57: ...Manual 0 2957 6 5 PARTS LISTS NOTE Illustration may vary slightly from unit 3 5 4 1 7 5 Art A 03717 6 2 2A OR 8...
Страница 62: ...PARTS LISTS 6 10 Manual 0 2957 This Page Left Blank...
Страница 71: ...Manual 0 2957 A 9 APPENDIX APPENDIX 7 INPUT DIODE PC BOARD LAYOUT Art A 03703 E18 E13 E5 E14 E16 E8 E6 19x1811...