TROUBLESHOOTING
4-8
Manual 0-2957
F. RUN / RAPID AUTO RESTART /SET switch in
RUN or RAPID AUTO RESTART position; AC
indicator
ON; TEMP , GAS
, and DC
indicators
OFF
A
Ar
t # A-03
9
86
1. Gas pressure too low
a. Set operating pressure per pressure setting la-
bel on power supply.
2. Faulty Components in Unit
Measure for 12 vdc from wire #10 to wire #11 at the
Gas Pressure Switch, located on the right side of
the unit.
a. If 12 vdc is present and pressure is above 50 psi
(3.4 bar), replace Gas Pressure Switch/Solenoid
Assembly. Refer to Section 5.08-A.
b. If pressure is above 50 psi (3.4 bar) and 12 vdc is
not present, replace the Logic PC Board.
c. Remove one wire from the pressure switch.
Check for ± 0 vdc at Main PC Board pin J24-3 to
J24-4 from the Logic PC Board. Refer to Main
PC Board Layout.
• If less than a volt, replace Logic PC Board.
Logic Board Layout
TP9
TP10
TP11
TP3
TP7
TP8
TP5
TP1
TP2
TP4
D13
TP6
Art # A-03654
D25
D33
P1-7
P1-9
Содержание CUTMASTER 81
Страница 2: ......
Страница 4: ......
Страница 16: ...INTRODUCTION 2 2 Manual 0 2957 This Page Left Blank...
Страница 20: ...DESCRIPTION 3 4 Manual 0 2957 This Page Left Blank...
Страница 40: ...TROUBLESHOOTING 4 20 Manual 0 2957 This Page Left Blank...
Страница 57: ...Manual 0 2957 6 5 PARTS LISTS NOTE Illustration may vary slightly from unit 3 5 4 1 7 5 Art A 03717 6 2 2A OR 8...
Страница 62: ...PARTS LISTS 6 10 Manual 0 2957 This Page Left Blank...
Страница 71: ...Manual 0 2957 A 9 APPENDIX APPENDIX 7 INPUT DIODE PC BOARD LAYOUT Art A 03703 E18 E13 E5 E14 E16 E8 E6 19x1811...