TROUBLESHOOTING
4-18
Manual 0-2957
Nominal
Input Voltage
Contactor
Points
Voltage
Range
208/230VAC
L1, L2
187-253VAC
400VAC
L1, L3
360-440VAC
415VAC
L1, L3
370-460VAC
460VAC
L1, L3
414-506VAC
Contactor Voltage Readings
Art # A-03194
Main Contactor
#13
#5
L1 L2 L3
T1
T2
T3
To E3
Connections to
Main PCB
#4
#12
To E1
To E2
Input Side
L1
L3
L2
400 / 415 / 460 / 600-Volt Main Input Contactor
(Three-Phase Input Power Shown)
Art # A-03212
L1 L2 L3 L4
T1
T2
T3
T4
#13
#12
#78
L1
L2
Input
Side
#5
#4
#3
#2
#1
Main Contactor
208/230-Volt Main Input Contactor
2.
Check for 28 VAC at J23-1 to J23-3 on the Main PC
Board.
a. If greater than 30 VAC, input line power is too
high.
b. If there is no AC power, check the fuse. If the
fuse is okay, the auxiliary transformer is faulty.
Replace the Main PC Board.
E. Gas Solenoid Circuit Test
Make the following voltage checks and replace the faulty
part as required.
1.
Place the RUN / RAPID AUTO RESTART / SET
Switch to the SET position.
2.
Measure for 28 VAC across Solenoid wires #8 and
#9. Refer to System Schematic in Appendix Sec-
tion.
• If 28 VAC is present, replace Solenoid/Pressure
Switch Assembly.
• If 28 VAC is not present, check for 65 psi (4.5
bar) at the pressure regulator.
3.
Check for less than 2 vdc at P1-7 to TP1 on Logic
Board.
• If less than 2 vdc, replace Main PC Board.
• If more than 2 vdc, replace Logic PC Board.
Содержание CUTMASTER 81
Страница 2: ......
Страница 4: ......
Страница 16: ...INTRODUCTION 2 2 Manual 0 2957 This Page Left Blank...
Страница 20: ...DESCRIPTION 3 4 Manual 0 2957 This Page Left Blank...
Страница 40: ...TROUBLESHOOTING 4 20 Manual 0 2957 This Page Left Blank...
Страница 57: ...Manual 0 2957 6 5 PARTS LISTS NOTE Illustration may vary slightly from unit 3 5 4 1 7 5 Art A 03717 6 2 2A OR 8...
Страница 62: ...PARTS LISTS 6 10 Manual 0 2957 This Page Left Blank...
Страница 71: ...Manual 0 2957 A 9 APPENDIX APPENDIX 7 INPUT DIODE PC BOARD LAYOUT Art A 03703 E18 E13 E5 E14 E16 E8 E6 19x1811...