REPLACEMENT PROCEDURES
5-6
Manual 0-2957
10. Connect wires per the chart.
Input Diode To M ain P CB Input Diode To M ain P CB
E 5
E 1
E 5
E 1
E 13
E 2
E 18
E 3
E 6, E 8
E 7
E 6, E 8
E 7
E 14, E 16
E 15
E 14, E 16
E 15
400V , 415V , 460V ,
600V Units
208/230V Units
CutM as ter 81 Input Diode Connec tions
E 13, E 18
E 2
For IGBTs:
a. Apply a round thermal pad to the heatsink
with a small piece of light-duty tape. The tape
must cover no more than 1/8" (3 mm) of the
edge of the thermal pad. Use the screw hole
in the heatsink as a guide to position the board.
Washer
Screw
Output Diode
or IGBT
Round
Thermal Pad
Art # A-03702
Tape
Tape
b. Secure replacement board(s) with the screw
removed previously. Ensure that the washer
is under the head of the screw.
9. Torque screw(s) to 17 in-lb. (1.9 Nm).
NOTE
Failure to torque properly will cause component
damage.
10. Connect wires per the chart.
IGBT A
Connector
To Main PCB
Connector
IGBT B
Connector
To Main PCB
Connector
J3
J25
J3
J31
J7
J30
J7
J26
E9, E11
E10
E9, E11
E27
E19, E21
E20
E19, E21
E30
E12, E17
E4
E12, E17
E23
IGBT A
IGBT B
CutMaster 81 IGBT Connections
11. Stand the unit upright; reinstall the cover.
E. Main Power PC Board Replacement
Follow the antistatic procedures in subsection 5.02.
1. Remove cover per subsection 5.04-A.
2. Remove the Logic PC Board per subsection 5.06-C.
3. Disconnect all wire and cable connections to the
Main PC Board. Refer to the Main PC Board Wir-
ing Diagrams in the Appendix Pages if necessary.
Straighten the connections to the smaller PC
Boards to be perpendicular to the Main PC Board.
5. Remove the two long Transformer screws secur-
ing the Transformer to the Center Chassis.
6. Remove the other screws securing the PC Board
to the Center Chassis.
Art # A-03165
Screw locations
7. Carefully remove the original PC Board from the
unit.
8. Transfer the Logic PC Board standoffs to the re-
placement Main PC Board.
9. Install the replacement PC Board by reversing the
steps above. It may be easier to install the PC
Board if the Power Supply is turned on its right
side first. Refer to the charts in subsection 5.06-D
for input diode and IGBT wiring connection
points.
F. EMI Filter Replacement (CE Units only)
1. Label the input power cable connections and the
cable connections to the main input contactor.
2. Disconnect all wire and cable connections to the
EMI Filter.
3. Remove the hardware securing the EMI Filter.
This hardware passes upward through the base
of the power supply.
4. Put the replacement EMI Filter in position and
secure it with the hardware removed in Step 3.
Содержание CUTMASTER 81
Страница 2: ......
Страница 4: ......
Страница 16: ...INTRODUCTION 2 2 Manual 0 2957 This Page Left Blank...
Страница 20: ...DESCRIPTION 3 4 Manual 0 2957 This Page Left Blank...
Страница 40: ...TROUBLESHOOTING 4 20 Manual 0 2957 This Page Left Blank...
Страница 57: ...Manual 0 2957 6 5 PARTS LISTS NOTE Illustration may vary slightly from unit 3 5 4 1 7 5 Art A 03717 6 2 2A OR 8...
Страница 62: ...PARTS LISTS 6 10 Manual 0 2957 This Page Left Blank...
Страница 71: ...Manual 0 2957 A 9 APPENDIX APPENDIX 7 INPUT DIODE PC BOARD LAYOUT Art A 03703 E18 E13 E5 E14 E16 E8 E6 19x1811...