INSTALLING THE VENTILATION

The range is equipped with a factory installed ventilator
intake and an exhaust plenum which will not be shipped
separately.  The plenum exhaust outlet is located below the
oven in the base area shown in Fig.14.  An Integral Blower
Model VTN30Q  or Remote Model VTR1000Q Blower
System must be installed with the range.  (Blower systems
are purchased separately).

INSTALLING AN INTEGRAL BLOWER

THE VTN30Q blower may be mounted prior to or after
range installation depending on duct and taping variables.
The integral blower housing inlet  (See Figure 15) fits over
the plenum outlet ring (Figure 14), and is secured to the
plenum with a blower mounting bracket.

The blower may be rotated in various directions to achieve
right side, left side, rear or floor venting.  See pages 10 to 12
for specific installation steps.

Threaded rods included in the blower kit will be secured to
the mounting nuts "A" or "B" shown in Figure 15.  Further
installation instructions are specified in the following
sections.

4.

The duct put into the unit inlet blower should be taped
at the joint and the inlet collar.

5.

Clearance to combustible material is 0".

6.

Run electrical conduit up through extruded hole in
bottom of the remote blower.  Connect it to the bottom
of the “J” box (Fig.13).

Figure 13

SAFETY WARNING: Before wiring the
unit, turn off the proper circuit at the
service box.

VENTILATION 

Figure 14 – Bottom View of Exhaust plenum

Figure 15 – Integral Blower Vent to

Side Back and Floor

Front

Up

B

A

A

Plenum

Exhaust

Outlet B

7.

Run five #14 AWS wires (white, red, blue, black and
green) to the conduit, (Fig.13). For the wire connection
between the remote blower and range see page 7 and
Figs. 8 & 9.

OFF

OFF

OF

F

OFF

OF

F

OFF

Mounting

Bracket

Threaded

Rods

Blower

Inlet

Содержание RDDS30V

Страница 1: ...GAZ Ne pas essayer d allumer aucun appareil Ne pas toucher aucun interrupteur lectrique ne pas utiliser aucun t l phone dans votre b timent Appeler imm diatement votre fournisseur de gaz du t l phone...

Страница 2: ...tion appropri e des gaz par le conduit de fum e chemin e des appaeils combustible pour viter le refoulement Suivre la directive des fabricants du mat riel chauffant et les normes de s curit tel que ce...

Страница 3: ...rface and the bottom of an unprotected wood or metal cabinet or 24 inches when bottom of wood or metal cabinet is protected by not less than 1 4 of flame retardant material covered with not less than...

Страница 4: ...ve the existing back brace see Figure 27 Page 18 and use floor mounted anti tip bracket see Figure 30 Page 19 NOTE Follow all measurements precisely If working with nonstandard cabinets take care to a...

Страница 5: ...au de 14 0 pounces du r gulateur du r servoir de gaz du propane WARNING Do not attempt any adjustment of the pressure regulator except conversion to propane AVERTISSEMENT Ne pas entreprener aucun ajus...

Страница 6: ...If local code requires separate ground separate white wire and bare gound wire connect white to white and ground bare wire separately GAS CONNECTION MODEL RDDS30V GAS CONNECTION For gas units a 1 2 N...

Страница 7: ...wer Cord Receptacle Integral Blower Front Rail 2 Units using Remote Blower a Wiring the Remote Blower Wire connections between the range and remote blower shall be made as follows 1 Remove plenum cove...

Страница 8: ...ust to roof angle Tape all joints to prevent air leaks NOTE The unit must be sealed between the roof or wall and the underside of the flange with roofing mastic to prevent leaks For installation on a...

Страница 9: ...ng See pages 10 to 12 for specific installation steps Threaded rods included in the blower kit will be secured to the mounting nuts A or B shown in Figure 15 Further installation instructions are spec...

Страница 10: ...nsure gasket between blower and plenum is compressed 1 Determine blower direction and cutout in cabinet as shown in Figs 16 17 Remove the existing 1 4 20 screws from either positions A or B and discar...

Страница 11: ...plenum outlet ring Figure 14 temporarily supporting blower with wood blocks 5 Place slot end of blower mounting bracket over rear mounting rod lower nut 6 Rotate blower mounting bracket under blower...

Страница 12: ...rod has one preset nut which shall be tightened against plenum 4 Place blower inlet over plenum outlet ring Figure 14 temporarily supporting blower with wood blocks 5 Place slot end of blower mounting...

Страница 13: ...to standard ducts See Figure 21 Exterior ducting may be routed right left rear up rear wall above and below floor line See Figure 22 VENTILATION Figure 21 Ducting Adapters Model RD7 Model RD310 REMOT...

Страница 14: ...will need to transition from other duct sizes to achieve the 10 diameter Be sure to use proper transitions from one size duct to another NOTE You need to calculate the equivalent lengths of straight d...

Страница 15: ...420 C F M BLOWER DUCT SIZING Based on the blower position determine the required straight duct length and size and the number and types of elbows or transitions Calculate the total equivalent length u...

Страница 16: ...16 BLOWER DUCT SIZING...

Страница 17: ...Cap Round to 3 1 4 x 10 Round to 3 1 4 x 10 90 Elbow 45 Elbow 3 1 4 x 10 to 10 Dia Model 310TR10 Equiv Length 1 Ft Fitting Straight Dia Length 6 5 Ft 7 4Ft 8 3 Ft Fitting Straight Dia Length 6 1 Ft 7...

Страница 18: ...shall allow the range back brace to slide under the anti tip bracket See Figure 26 c If necessary add spacer between bracket and wall to insure anti tip bracket engagement d Slide range into position...

Страница 19: ...LATION Figure 29 Placement of Anti tip Bracket to Floor TopView 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 1234...

Страница 20: ...dor reserves the right to change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are transported from the United Sta...

Отзывы: