2

CAUTION: To reduce risk of fire and to properly exhaust
air, be sure to duct air outside. Do not vent exhaust air
into spaces within walls or ceilings or into attics, crawl
spaces, or garages.

WARNING: TO REDUCE THE RISK OR FIRE,
ELECTRIC SHOCK. OR INJURY TO PERSONS,
OBSERVE THE  FOLLOWING:

a) Installation Work And Electrical Wiring Must Be Done

By Qualified Person(s) In Accordance With All
Applicable Codes And Standards, Including Fire-Rated
Construction.

b) Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting.  Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.

c) When cutting or drilling into wall or ceiling, do not

damage electrical wiring and other hidden utilities.

d) Ducted fans must always be vented to the outdoor.

SAFETY WARNINGS

AVERTISSEMENT  - Pour réduire le risque
d'incendie, utiliser seulement le travail du
conduit métallique.

a) Le Travail d’Installation et de Câblage Éectrique Doit

Être Fait Par les Personne(s) Qualifiées Conformément
à Tous les Codes & Normes Applicables, y Compris la
Construction Calculée à Feu.

b). Il faut suffisamment d'air pour permettre une bonne

combustion et une évacuation appropriée des gaz par
le conduit de fumée (cheminée) des appaeils à
combustible pour éviter le refoulement. Suivre la
directive des fabricants du matériel chauffant et les
normes de sécurité tel que ceux publiées par
l’Association du Protection de Feu National (NFPA),
et la Société Américaine pour les Ingénieurs de
Chauffage, de Réfrigération et de Climatisation
(ASHRAE), et les autorités des codes locales.

c) En coupant our en forant dans un mur ou dans un

plafond, ne pas endommager le câblage électrique et
des autres utilités cachées.

d) Les ventilateurs canalisé doivent être toujours

déchargés.

AVERTISSEMENT: – POUR RÉDUIRE LE RISQUE
D'INCENDIE, DE CHOC ÉLECTRIQUE, OU DE LA
BLESSURE AUX PERSONNES, OBSERVER LES
SUIVANTS:

ATTENTION: Pour réduire le risquie d'incendie et alfin
que l'air s'échappe bien, s'assurer de diriger l'air vers
l'extérieur – N'evacuez pas l'air vicié dans le vide intérieur
des murs, le vide des plafonds, les greniers, les vides sanitaires
ni le garages.

AVERTISSEMENT:  L'installation inexacte,
l'ajustment, la modification, le service ou
l'entretien peut causer la blessure ou la
propriété endommagée.  Se référer â ce
manuel. Pour l'assistance ou l'information
additionnelle consulter un installateur qualifié,
une agence de ser vice , le fabricant (le
marchand) ou le fournisseur de gaz.

WARNING:  Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage.  Refer to this
manual.  For assistance or additional
information consult a qualified installer, service
agency, manufacturer (dealer) or the gas
supplier.

WARNING: To Reduce the risk of fire, use only
metal ductwork.

Содержание RDDS30V

Страница 1: ...GAZ Ne pas essayer d allumer aucun appareil Ne pas toucher aucun interrupteur lectrique ne pas utiliser aucun t l phone dans votre b timent Appeler imm diatement votre fournisseur de gaz du t l phone...

Страница 2: ...tion appropri e des gaz par le conduit de fum e chemin e des appaeils combustible pour viter le refoulement Suivre la directive des fabricants du mat riel chauffant et les normes de s curit tel que ce...

Страница 3: ...rface and the bottom of an unprotected wood or metal cabinet or 24 inches when bottom of wood or metal cabinet is protected by not less than 1 4 of flame retardant material covered with not less than...

Страница 4: ...ve the existing back brace see Figure 27 Page 18 and use floor mounted anti tip bracket see Figure 30 Page 19 NOTE Follow all measurements precisely If working with nonstandard cabinets take care to a...

Страница 5: ...au de 14 0 pounces du r gulateur du r servoir de gaz du propane WARNING Do not attempt any adjustment of the pressure regulator except conversion to propane AVERTISSEMENT Ne pas entreprener aucun ajus...

Страница 6: ...If local code requires separate ground separate white wire and bare gound wire connect white to white and ground bare wire separately GAS CONNECTION MODEL RDDS30V GAS CONNECTION For gas units a 1 2 N...

Страница 7: ...wer Cord Receptacle Integral Blower Front Rail 2 Units using Remote Blower a Wiring the Remote Blower Wire connections between the range and remote blower shall be made as follows 1 Remove plenum cove...

Страница 8: ...ust to roof angle Tape all joints to prevent air leaks NOTE The unit must be sealed between the roof or wall and the underside of the flange with roofing mastic to prevent leaks For installation on a...

Страница 9: ...ng See pages 10 to 12 for specific installation steps Threaded rods included in the blower kit will be secured to the mounting nuts A or B shown in Figure 15 Further installation instructions are spec...

Страница 10: ...nsure gasket between blower and plenum is compressed 1 Determine blower direction and cutout in cabinet as shown in Figs 16 17 Remove the existing 1 4 20 screws from either positions A or B and discar...

Страница 11: ...plenum outlet ring Figure 14 temporarily supporting blower with wood blocks 5 Place slot end of blower mounting bracket over rear mounting rod lower nut 6 Rotate blower mounting bracket under blower...

Страница 12: ...rod has one preset nut which shall be tightened against plenum 4 Place blower inlet over plenum outlet ring Figure 14 temporarily supporting blower with wood blocks 5 Place slot end of blower mounting...

Страница 13: ...to standard ducts See Figure 21 Exterior ducting may be routed right left rear up rear wall above and below floor line See Figure 22 VENTILATION Figure 21 Ducting Adapters Model RD7 Model RD310 REMOT...

Страница 14: ...will need to transition from other duct sizes to achieve the 10 diameter Be sure to use proper transitions from one size duct to another NOTE You need to calculate the equivalent lengths of straight d...

Страница 15: ...420 C F M BLOWER DUCT SIZING Based on the blower position determine the required straight duct length and size and the number and types of elbows or transitions Calculate the total equivalent length u...

Страница 16: ...16 BLOWER DUCT SIZING...

Страница 17: ...Cap Round to 3 1 4 x 10 Round to 3 1 4 x 10 90 Elbow 45 Elbow 3 1 4 x 10 to 10 Dia Model 310TR10 Equiv Length 1 Ft Fitting Straight Dia Length 6 5 Ft 7 4Ft 8 3 Ft Fitting Straight Dia Length 6 1 Ft 7...

Страница 18: ...shall allow the range back brace to slide under the anti tip bracket See Figure 26 c If necessary add spacer between bracket and wall to insure anti tip bracket engagement d Slide range into position...

Страница 19: ...LATION Figure 29 Placement of Anti tip Bracket to Floor TopView 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 1234...

Страница 20: ...dor reserves the right to change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are transported from the United Sta...

Отзывы: