BLOWER ELECTRICAL CONNECTION
The electrical connection of either the integral or remote
blower shall be made on the right front corner of the plenum
as shown in Figures 7 & 8.
Based on the type of ventilation (integral or remote blower)
proceed with directions either 1 or 2.
1. Units using Integral Blower:
The integral blower is furnished with a cord and connector.
Insert cord connector into receptacle located in lower right
plenum bottom. See Figure 7.
ELECTRICAL CONNECTION (ALL MODELS)
Figure 7 – Blower Cord Connection
OVEN FRONT
Plenum Opening
Blower Cord
Receptacle
Integral Blower
Front Rail
2. Units using Remote Blower:
a) Wiring the Remote Blower
Wire connections between the range
and remote blower shall be made as
follows:
1. Remove plenum cover and
front rail for access to range
blower wiring. (See Figure 8.)
2. Grasp the five wires and cut
as close to molded connector as
possible.
3. Remove plug from electric
"knockout" from plenum bottom
(right front corner). Secure
remote blower flex conduit/wiring
to plenum conduit connector,
4. Connect color coded range
wires to remote blower wires
using wire nuts or approved splices.
(See Figure 9.)
5. Reinstall plenum cover and
front rail.
Figure 8 – Remote Blower Wiring
Figure 9 – Range - Remote Blower Electrical Connection
Range Front
Screws
Plenum Opening
Wiring
Compartment
To Remote
Blower
Duct
Attachment Box
Removable
Plenum Cover
Removable
Front Rail
K.O.'s
Location