The range is equipped with a retractable rear ventilation
intake and integral plenum.  The plenum outlet, located under
the range may be connected to an integral blower or a
remote blower (purchased separately).  See Pages 8 – 17.

SAFETY WARNINGS

No Clearance

to Wall

 Required

No Clearance

to Wall

 Required

30"  Min.

30" Minimum

Centered

Safety Instructions and Applicable Codes ........................................................................................................... 1,2
Ventilation and Cabinet Considerations ............................................................................................................. 3,4
Gas Connections Model RDDS30VQ ................................................................................................................. 5,6
Electrical Connections ............................................................................................................................................ 6,7
Installing the Ventilation .......................................................................................................................................... 8-9
Ventilation ............................................................................................................................................................... 9-14
Blower Duct Sizing .............................................................................................................................................. 15-17
Anti-Tip Bracket Installation ............................................................................................................................. 18-19

To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storage space located
above the surface units should be avoided.

Instructions  are based on Standard American cabinets
measuring 36" high x 24" deep.

CABINET

This unit is designed for installation in a countertop near
adjacent walls and projecting surfaces constructed of
combustible materials.  There must be a minimum clearance
of 30 inches between the top of the cooking surface and
the bottom of an unprotected wood or metal cabinet; or
24 inches when bottom of wood or metal cabinet is
protected by not less than 1/4" of flame retardant material
covered with not less than No. 28 MSG sheet metal, 0.015
inch stainless steel, or 0.024 inch aluminum or copper.  (See
Figure 1).  The minimum horizontal distance from the side
and back edge of the unit to adjacent vertical combustible
walls are as follows:  Zero clearance is permitted on rear,
right and left walls.

For the cabinets over the cooking surface and the adjacent
cabinets, the maximum cabinet depth from back wall is 13".

Figure 1 Installation Guide

VENTILATION AND CABINET CONSIDERATIONS 

TABLE OF CONTENTS 

WARNING:  This unit is designed as a cooking
appliance.  Based on safety consideration, never
use it for warming or heating a room.

WARNING:  DO NOT LIFT RANGE BY
DOOR HANDLE.  Remove the door before
removing the unit from the pallet to provide
more stability before installation.  See 'Do-It-
Yourself Maintenance: Removing the Oven
Door' in the Care and Use Manual.

AVERTISSEMENT: L'appareil est pour la
cuisson.  Basé sur les considérations de sécurité,
ne jamais utiliser le Cooktop pour chauffer une
chambre.

AVERTISSEMENT:  NE PAS ÉLEVER LA
CUISINÈRE PAR LA POIGNÉE DE LA PORTE.
Énlever la porte avant d'énlever l'appareil du
plateforme de bois pouvoir plus de stabilité
avant d'installation.  Lire ce manuel de Soin y
Utilisation.

Содержание RDDS30V

Страница 1: ...GAZ Ne pas essayer d allumer aucun appareil Ne pas toucher aucun interrupteur lectrique ne pas utiliser aucun t l phone dans votre b timent Appeler imm diatement votre fournisseur de gaz du t l phone...

Страница 2: ...tion appropri e des gaz par le conduit de fum e chemin e des appaeils combustible pour viter le refoulement Suivre la directive des fabricants du mat riel chauffant et les normes de s curit tel que ce...

Страница 3: ...rface and the bottom of an unprotected wood or metal cabinet or 24 inches when bottom of wood or metal cabinet is protected by not less than 1 4 of flame retardant material covered with not less than...

Страница 4: ...ve the existing back brace see Figure 27 Page 18 and use floor mounted anti tip bracket see Figure 30 Page 19 NOTE Follow all measurements precisely If working with nonstandard cabinets take care to a...

Страница 5: ...au de 14 0 pounces du r gulateur du r servoir de gaz du propane WARNING Do not attempt any adjustment of the pressure regulator except conversion to propane AVERTISSEMENT Ne pas entreprener aucun ajus...

Страница 6: ...If local code requires separate ground separate white wire and bare gound wire connect white to white and ground bare wire separately GAS CONNECTION MODEL RDDS30V GAS CONNECTION For gas units a 1 2 N...

Страница 7: ...wer Cord Receptacle Integral Blower Front Rail 2 Units using Remote Blower a Wiring the Remote Blower Wire connections between the range and remote blower shall be made as follows 1 Remove plenum cove...

Страница 8: ...ust to roof angle Tape all joints to prevent air leaks NOTE The unit must be sealed between the roof or wall and the underside of the flange with roofing mastic to prevent leaks For installation on a...

Страница 9: ...ng See pages 10 to 12 for specific installation steps Threaded rods included in the blower kit will be secured to the mounting nuts A or B shown in Figure 15 Further installation instructions are spec...

Страница 10: ...nsure gasket between blower and plenum is compressed 1 Determine blower direction and cutout in cabinet as shown in Figs 16 17 Remove the existing 1 4 20 screws from either positions A or B and discar...

Страница 11: ...plenum outlet ring Figure 14 temporarily supporting blower with wood blocks 5 Place slot end of blower mounting bracket over rear mounting rod lower nut 6 Rotate blower mounting bracket under blower...

Страница 12: ...rod has one preset nut which shall be tightened against plenum 4 Place blower inlet over plenum outlet ring Figure 14 temporarily supporting blower with wood blocks 5 Place slot end of blower mounting...

Страница 13: ...to standard ducts See Figure 21 Exterior ducting may be routed right left rear up rear wall above and below floor line See Figure 22 VENTILATION Figure 21 Ducting Adapters Model RD7 Model RD310 REMOT...

Страница 14: ...will need to transition from other duct sizes to achieve the 10 diameter Be sure to use proper transitions from one size duct to another NOTE You need to calculate the equivalent lengths of straight d...

Страница 15: ...420 C F M BLOWER DUCT SIZING Based on the blower position determine the required straight duct length and size and the number and types of elbows or transitions Calculate the total equivalent length u...

Страница 16: ...16 BLOWER DUCT SIZING...

Страница 17: ...Cap Round to 3 1 4 x 10 Round to 3 1 4 x 10 90 Elbow 45 Elbow 3 1 4 x 10 to 10 Dia Model 310TR10 Equiv Length 1 Ft Fitting Straight Dia Length 6 5 Ft 7 4Ft 8 3 Ft Fitting Straight Dia Length 6 1 Ft 7...

Страница 18: ...shall allow the range back brace to slide under the anti tip bracket See Figure 26 c If necessary add spacer between bracket and wall to insure anti tip bracket engagement d Slide range into position...

Страница 19: ...LATION Figure 29 Placement of Anti tip Bracket to Floor TopView 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 12345678901 1234...

Страница 20: ...dor reserves the right to change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are transported from the United Sta...

Отзывы: