6
■
ELECTRICAL SUPPLY
(Electric and Gas models)
•
The Range, provided with a 4' length of flex conduit and
conductors, shall be connected to a junction box
specified below.
•
The electrical supply should be 3 wire, single phase, A.C.
with a grounded neutral.
•
For electrical connection, a 4" x 4" junction box should
be placed within the shaded area. (See Figure 6). The
box has to be recessed into the wall. The maximum
protrusion of flex conduit and connector shall not
exceed 1-3/4" as shown in Figure 6.
GROUNDING
The unit is supplied with a flexible metallic conduit.
•
If flexible metallic conduit is connected to a grounded
metallic conduit system, oven is grounded through the
metallic conduit.
•
If local code permits grounding through the neutral,
connect both bare ground wire and white wire to white
wire neutral supply.
•
If local code requires separate ground, separate white
wire and bare gound wire, connect white to white and
ground bare wire separately.
GAS CONNECTION (MODEL RDDS30V)
GAS CONNECTION
For gas units, a 1/2" N.P.T. wall gas supply can lie anywhere
within the shaded area. (See Figure 4). Attach a 1/2" N.P.T.
shut-off valve to the wall stub-out. The other end of the
valve should be connected to a 3/8" flexible gas connector -
(not supplied). The flexible connector shall be secured to
the pressure regulator located in the lower left area of the
range shown in Figure 5.
Figure 6 – Electrical Location
1-3/4"
Max Protrusion
From Wall
4-1/8" From Cabinet
Both Sides
3" From Floor
32" From
Floor
MODEL
VOLTS
HZ
RATING
CIRCUIT
KW
REQUIRED
RDDS30V
120/240
60
5.1
30 Amps
120/208
60
4.0
20 Amps
RED30V
120/240
60
12.0
50 Amps
120/208
60
9.8
50 Amps
■
ELECTRICAL CONNECTION (ALL MODELS)
Figure 5 – Gas Supply Flexible
Connector Routing
Front
Up
Regulator
Flexible
Connector
To Shut Off
Valve
View of Bottum Side From Left Front of Range