Service Manual for the Thermador Pro Grand Next Generation 48-Inch Natural Gas and LP Gas Ranges, Models:
PRG486JDG/01, PRL486JDG/01
58300000159722_ARA_EN_D
Page 44 of 92
8. Use an adjustable wrench to remove the flared adapter from the
elbow connecting piece (see Figure 57).
9. Remove and retain the two screws holding each manifold bracket
onto the range chassis, and then pull the manifold forward to
remove it (with the elbow connecting piece attached). See
Figure 57.
Figure 57: Bake and Broil Manifold with Fittings
1
Flared adapter (shown attached to gas flex line)
2
Elbow connecting piece
3
Manifold for bake and broil burners
4
Screws (2) on each manifold bracket (2)
10. Use an adjustable wrench to remove the elbow connecting piece.
11. Use an adjustable wrench to remove the three fittings on the
manifold (see Figure 58).
12. Replace the manifold if needed.
Gas Leaks
With electrical power off, carefully check for gas leaks at each gas
component that was removed, replaced, or otherwise serviced using a
gas leak detector (electronic leak detectors are highly recommended)
or bubble test.
Figure 58: Removing Fittings on the Manifold