Page 26 of 50
KNX presence detector PlanoCentro A-KNX
2.4.13 Remote control
Parameter name
Values
Application
Teach-in brightness level via
user remote control
disabled
enabled
This function is not available with the SendoClic user remote control.
Switching/dimming A
Switching/dimming B
External 1 switching/dimming
External 2 switching/dimming
External blinds 1
External blinds 2
The IR group addresses of the presence detector and the SendoClic
must correspond so that lighting groups or external channels can be
operated.
For detailed information on the application of IR group addresses see
chapter 7 „Benutzer-Fernbedienung SendoClic integrieren“ page <?>
The same specification of IR group addresses is to be defined in the ETS,
which were set using the coding switch on the SendoClic user remote
control.
Inactive
The relevant channel is not allocated an IR group address and cannot be
influenced by the user remote control.
I , II , III The relevant challenge is allocated an IR group address.
The channel reacts to the commands from the user remote control.
2.4.14 Scenes
Parameter name
Values
Application
Scene control
The presence detector has a simple, internal scene component. On a
scene are values for the light outputs stored (On, Off with switching
operating mode, percentage values with constant light control).
End
-
Absent
-
ON / OFF with the SendoClic user remote control
internal scenes
The <Define scenes with> parameter is faded in.
The scenes can be called up by pressing the scene buttons on the Sen-
doClic user remote control or via a telegram to the scene object.
Send scene The <Scene number key scene 1> and <Scene number key scene 2>
parameters are faded in.
Scene numbers can be allocated to the scene 1 and scene 2 keys on the
SendoClic user remote control.
Scene component This enables the control of an external scene component. This requires
the use of the SendoClic user remote control. An OFF telegram is sent
when scene key 1 on the SendoClic is pressed and pressing scene key 2
raises an ON telegram.
Scene number
key scene 1
Scene number
key scene 2
Inactive
No scene number is sent.
1–64 The set scene number is sent via object 24 (1 byte) by pressing the
scene keys on the SendoClic user remote control. The scene statuses can
be stored with the SendoClic. See the SendoClic operating instructions.
Define scenes with
ETS
The following parameters are faded in:
-
<Output value scene 1, light A>
-
<Output value scene 2, light A>
-
<Output value scene 1, light B>
-
<Output value scene 2, light B>
The output values are fixed by the values configured in the ETS.
Remote control The output values are stored with the user remote control. See the
SendoClic operating instructions.