Menu/
INSTRUCTION
C: Commands
A: Activities
Submenu
DVOR 432
Operation and Maintenance
Alignment Procedure
Annex Nextfield
AN-21
Ed. 01.04
4.6
SETTING OF TRANSMITTERS AND MONITORS
4.6.1
Setting of TX1 with Monitor 1
4.6.1.1
Basic Settings
a) Connect the power meter to the CSB output.
b) Switch on TX1.
C
Switch TX1 On
c) Set 30 Hz AM mod. depth to 0 %.
A/TS
T1 Mod. Depth
30Hz AM 0 %
d) Set identity mod. depth to 0 %.
A/TS
T1 Mod. Depth
Identity 0 %
e) Set voice mod. depth to 0 %.
A/TS
T1 Mod. Depth Voice
0 %
f)
Set CSB power to nominal value (30 W or up to 100 W).
A/TS
T1 Carrier Power
Measure the power.
---,- W
NOTE:
If there is a difference between the nominal power and the meaĆ
sured power adjust the power by means of R1 of the Control CouĆ
pler (CCP-D), refer to Fig. 4-6 (BP-T,X16).
g) Preset levels of blending functions (sine and cosine) for SB1
and SB2:
- SB1-S
A/TS
T1 SBA SINUS Blen-
ding --,-%
- SB1-C
A/TS
T1 SBA COSINUS
Blending --,-%
- SB2-S
A/TS
T1 SBB SINUS Blen-
ding --,-%
- SB2-C
A/TS
T1 SBB COSINUS
Blending --,-%
NOTE:
Up to 50 W: 30 %
,
with 100 W: 50 %
.
h) Set SB1- and SB2-power to 40 %:
- SB1
A/TS
T1 SBA Power Level
40 %
- SB2
A/TS
T1 SBB Power Level
40 %
i)
Switch off TX1.
C
Switch TX1 Off
j)
Disconnect the power meter.
Содержание DVOR 432
Страница 2: ......
Страница 4: ......
Страница 16: ...DVOR 432 Table of Contents Operation and Maintenance X Ed 01 04 ...
Страница 38: ...DVOR 432 General Information Operation and Maintenance 1 6 Ed 01 04 ...
Страница 40: ...DVOR 432 General Information Operation and Maintenance 1 8 Ed 01 04 ...
Страница 46: ......
Страница 66: ...DVOR 432 Installation Operation and Maintenance 2 24 Ed 01 04 ...
Страница 74: ......
Страница 136: ...DVOR 432 Installation Operation and Maintenance 4 32 Ed 01 04 ...
Страница 172: ...DVOR 432 Repairs Operation and Maintenance 6 22 Ed 01 04 ...
Страница 186: ...DVOR 432 Repairs Operation and Maintenance 6 36 Ed 01 04 ...
Страница 192: ...DVOR 432 Installation Operation and Maintenance Annex Nextfield AN 4 Ed 01 04 ...
Страница 194: ......
Страница 195: ...DVOR 432 Operation and Maintenance Annex Nextfield L 1 Ed 01 04 CHAPTER 2 CHAPTER 3 For Chapter numbering only ...
Страница 196: ...DVOR 432 General Operation and Maintenance Annex Nextfield L 2 Ed 01 04 ...
Страница 204: ...DVOR 432 Alignment Procedure Operation and Maintenance Annex Nextfield AN 14 Ed 01 04 ...
Страница 234: ...DVOR 432 Maintenance Operation and Maintenance Annex Nextfield AN 44 Ed 01 04 ...