![Thales DVOR 432 Скачать руководство пользователя страница 109](http://html.mh-extra.com/html/thales/dvor-432/dvor-432_technical-manual_1099172109.webp)
DVOR 432
Operation and Maintenance
Installation
4-5
Ed. 01.04
4.2
FIRST SWITCHING ON
4.2.1
Status of the System
- Mains off
- Battery fuse switches open (used for emergency battery, battery fuse box, shelter)
- POWER-switches on BCPS (ACC modules, transmitter cabinet) in position OFF
- PMM: switches NAV, TX1, TX2 (transmitter cabinet) in position OFF
4.2.1.1
Special Jumper Settings before Start Up
Individual jumpers have to be set before the first switching on. These are concerned with the enabling
of backup batteries for non volatile memory (LCP, MSP-VD/1,2, MSG-C/1,2) and the emergency
battery management (CSL). The location of jumpers is shown in section 6.2.4:
- LCP: Set jumper X36 (enabling backup battery for RTC).
- MSP-VD (MSP-D): Set jumper X7 on both boards (enabling backup battery).
- MSG-C: Set jumper X7 on both boards (enabling backup battery).
- CSL: Set jumper X18 (enabling cutoff for over discharge protection of emergency battery).
- CSL: Set jumper X22 (enabling automatic restore).
- CSL: Select minimal battery voltage with jumper X19,20,21 for standard over discharge protection.
4.2.2
Switching On
a) Connect PC serial interface connector (e.g. COM1) to connector Local PC on top of the cabinet
using an interface cable (zero modem cable).
b) Switch on mains and set POWER-switches of BCPS (ACC modules, cabinet) to position ON.
c) Close battery fuse switches (battery fuse box, inside shelter).
d) Set switches TX1/TX2 on PMM (cabinet, front side) to position ON.
e) Set main switch NAV on PMM (cabinet, front side) to position ON. During initialization of the LCP
a buzzer signal is set.
f) Switch to local control with the key-lock switch on the Local Control Interface (LCI).
4.2.3
Preparing the Installation SITE with PC and ADRACS
a) Switch on the PC and run Windows operating system.
NOTE:
Installation and use of the PC User Programis described in the Technical Manual
ADRACS
(chapter 1, sect. 1.4 Installation, chapter 2, Functions), more details on set up
of NAV installation is given in section 1.5 of ADRACS manual. It is recommended to beĆ
come familiar with the menus of ADRACS before performing the first set up procedure.
b) Click
Start
button, select
Programs
, programgroup
Adracs Remote Controlling
, program
Adracs
Remote Controlling Software
. The 'Adracs - Select Configuration' window appears.
c) Click on configuration type 'STANDARD' or on predefined configuration type and confirmwith
OK
button. The Main Status window of ADRACS appears.
Содержание DVOR 432
Страница 2: ......
Страница 4: ......
Страница 16: ...DVOR 432 Table of Contents Operation and Maintenance X Ed 01 04 ...
Страница 38: ...DVOR 432 General Information Operation and Maintenance 1 6 Ed 01 04 ...
Страница 40: ...DVOR 432 General Information Operation and Maintenance 1 8 Ed 01 04 ...
Страница 46: ......
Страница 66: ...DVOR 432 Installation Operation and Maintenance 2 24 Ed 01 04 ...
Страница 74: ......
Страница 136: ...DVOR 432 Installation Operation and Maintenance 4 32 Ed 01 04 ...
Страница 172: ...DVOR 432 Repairs Operation and Maintenance 6 22 Ed 01 04 ...
Страница 186: ...DVOR 432 Repairs Operation and Maintenance 6 36 Ed 01 04 ...
Страница 192: ...DVOR 432 Installation Operation and Maintenance Annex Nextfield AN 4 Ed 01 04 ...
Страница 194: ......
Страница 195: ...DVOR 432 Operation and Maintenance Annex Nextfield L 1 Ed 01 04 CHAPTER 2 CHAPTER 3 For Chapter numbering only ...
Страница 196: ...DVOR 432 General Operation and Maintenance Annex Nextfield L 2 Ed 01 04 ...
Страница 204: ...DVOR 432 Alignment Procedure Operation and Maintenance Annex Nextfield AN 14 Ed 01 04 ...
Страница 234: ...DVOR 432 Maintenance Operation and Maintenance Annex Nextfield AN 44 Ed 01 04 ...