IOM CRUZcontrol® Generation2 for NBC
P/N: 1118211
Revision Date: 05/31/2019
Page
24
of
66
4.7: T
ERMINAL AND
J
UMPER
D
ESCRIPTIONS
Terminal Descriptions
TB1
Single release, Logic interrupt, Pulse release.
This terminal is an isolated input; it must be used when signal voltage is from a
supply that is different than the supply powering CRUZcontrol logic assemblies.
It can be used when signal voltage is from same power supply that is powering
CRUZcontrol logic assemblies.
TB2
Slug release.
This terminal is an isolated input; it must be used when signal voltage is from a
supply that is different than the supply powering CRUZcontrol logic assemblies.
It can be used when signal voltage is from same power supply that is powering
CRUZcontrol logic assemblies.
TB3
Zone Status (TB3 only available on full function module)
This terminal is an isolated output; it must be used when signal voltage is from a
supply that is different than the supply powering CRUZcontrol logic assemblies.
It can be used when signal voltage is from same power supply that is powering
CRUZcontrol logic assemblies.
TB4
Inputs
This terminal is a non-isolated input; it must be used when signal voltage is from
same power supply that is powering CRUZcontrol logic assemblies.
TB5
Outputs
This terminal is a non-isolated outputs; output signal voltage is from same power
supply that is powering CRUZcontrol logic assemblies.