The Function Module provides electrical isolation for external controls and creates controllable zones to
facilitate CRUZcontrol applications.
Function Module Types
There are two different Function Modules, each providing certain of functions.
Table 3: Function Module Functions
Single
Release
Slug
Release
Pulsed
Release
Zone
Stop
Zone
Delay
Logic
Interrupt
Slug
Interrupt
Zone
Status
Full Function
Module
x
x
x
x
x
x
x
x
Release
Function
Module
x
x
x
x
x
Function Module Functions
Single Release
Definition
Only the discharge zone releases, when the discharge photoeye is clear the next
zone releases. The discharge zone will continue to release until the release signal
is removed.
Configuration The logic assemblies must be in basic mode (mode LED is green).
When releasing from the discharge end of the conveyor line all jumper terminals
should be on pins 1-2.
User Action
Apply a high (24Vdc/120Vac) release signal to TB1, 1-2 if using isolated inputs
Or
Apply a high (24Vdc) release signal to TB4, 3 if using non-isolated input.