CONFIGURING CH1 MEASUREMENT TASK & SAMPLING
RATE PROCEDURE
Pass Brightness
Mode, Calibration
Mode, Code 1,
and enter Code 2
Save setting and
enter Code 3
Set Code 2 to [000]:
1st Digit = 0 Selects 10
samples/sec (60 Hz)
2nd Digit = 0 Selects voltage, current
3rd Digit = 0 Selects no
function
Step 5
Exit Code 3.
Return to
Operational
Display
To
Step
5
Example
Operational Display
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
Step 4
Step 3
Step 1
Step 2
Operational Display
Enter Brightness
Mode
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
Press
3
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
Press
at same
time
Press
at same
time
Press
at same
time
Press
at same
time
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
Press
1
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
OR
CONFIGURE CH1
MEASUREMENT
TASK & SAMPLING
RATE
SP1 SP2 SP3 SP4 SP5 SP6
Prog.
Initial Setup Procedures
[CodE_2] - Channel 1 Measurement Task & Sampling Rate
FOR VOLTAGE
0 No function
1 Peak detector
2 Pressure with Auto-cal
FOR THERMOCOUPLE
0 Type J
1 Type K
2 Type R
3 Type S
4 Type T
5 Type B
6 Type N
7 Select user defined table set up in CAL
[24X]
FOR RTD TYPE (2-, 3-, 4- WIRE)
0 Resistance
1 RTD 385
2 RTD 392
3 RTD 120
4 Cn 10
FREQUENCY RANGE
0 99.999 Hz range from 0.010 Hz
1 99.999 Hz range from 2.000 Hz
2 999.99 Hz range from 0.01 Hz
3 999.99 Hz range from 2.00 Hz
4 9999.9 Hz range from 0.1 Hz
5 9999.9 kHz range from 2.0 Hz
6 99 kHz range from 1 Hz (1 s gate)
7 655.35 kHz range from 10 Hz (0.1 s gate)
PERIOD MEASUREMENT
0 99.999 s
1 9.9999 s
2 999.99 ms
3 99.999 ms
COUNTER/RESIDENT TIMER/CLOCK
0 Counter input with 16 bit Pre-scaler
1 Setting of 16-bit Pre-scaler
2 Debounced Counter with Pre-scaler
3 Up/Down Counter with Pre-scaler
4 0.1 sec Timer with Pre-scaler
5 –
6 External 24-hour clock
7 Internal 24-hour clock
ANALOG SAMPLE RATE
MEASUREMENT TASK
0 Voltage, Current
1 TC (3rd digit selects type of TC)
2 RTD 3-wire (3rd digit selects type of RTD)
3 RTD 2- or 4-wire (3rd digit selects type of RTD)
4 Frequency
5 Period
6 Counter
7 Smart Input Module
CODE 2 – CHANNEL 1 MEASUREMENT TASK AND SAMPLING RATE
SMART INPUT MODULE
0 Output Register 1
1 Output Register 2
2 Output Register 3
3 Output Register 4
4 Output Register 5
5 Output Register 6
6 Output Register 7
7 Smart Input Module Setup.
THIRD DIGIT
FIRST DIGIT
SECOND DIGIT
Example Procedure:
Configure CH1 for a voltage input with 10 samples/second (60
Hz) sampling rate and output rate of 0.1 seconds by setting
Code 2 to [
000
].
The Tiger 320 Series meter can be configured to measure almost
any input signal. The measurement task and sampling rate for
Channel 1 (CH1) is configured in the three digits of Code 2. The
diagram below lists the available configuration selections in Code 2.
0 Sample Rate: Typically 10 samples/second (60 Hz)
Output Rate: 0.1 seconds
See Example
1 Sample Rate: Typically 10 samples/second (50 Hz)
Output Rate: 0.1 seconds
See Example
2 Sample Rate: Typically 10 samples/second (60 Hz)
Output Rate: 10 millisecs
See Example
3 Sample Rate: Typically 10 samples/second (50 Hz)
Output Rate: 10 millisecs
See Example
Note:
Output Rate refers to setpoint and macro outputs, and input
rates from smart input modules.
Note:
All above sample rates are quoted for single channel opera-
tion. Where more than one channel is available, sample rates
are divided by the number of active channels. See Example.
1 Channel = 10 samples/second
2 Channels = 5 samples/second
3 Channels = 3.33 samples/second
4 Channels = 2.5 samples/second
Example: 10 Samples/Second
1 =
0.1 second
10 =
1 second
600 =
1 minute
36000 = 1 Hour***
X61 Sets Prescaler
Use
buttons to set
prescale values
START HERE
P
Press
Use the
buttons to set the
required smart input module code
(0 to 377). See
I-Series Input
Module Guide (Z87)
for code
details.
***Note: For the 1 hour
setting, the scale factor
for CH1 must be set to
0.1 in the calibration
mode setting [111].