Step 5: Setting Dip Switches on the Interface Adapter Pod (XDS522A Only)
1-13
Installing the XDS522/XDS522A Hardware
To configure the pipeline flattener mode for the XDS522A, take the following
steps:
1) Set switches S1 to S4, S7, and S8 to the following defaults, or to the set-
tings you need:
S1 Down
S2 Down
S3 Down
S4 Up
S7 Down
S8 Down
2) Set switches S5 and S6 for the flattener mode you want, as listed in the
following table:
Mode
Switch
Setting
Flat multi word
S5
S6
Up
Down
Flat first word
S5
S6
Up
Up
Unflattened
S5
S6
Down
Down
3) Specify the flattener mode to the BTT software. Include the –r
n option on
the command line when you invoke the BTT software. Use one of the fol-
lowing:
–r3
Unflattened mode
–r4
Flat first word mode
–r5
Flat multi word mode